5 - 28
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
CHAPTER 5 TROUBLESHOOTING
•
How to adjust the position
1) Remove the upper delivery cover and front
delivery cover.
2) Loosen the fixing screw
and rotate the
adjusting screw
to move the sensor
mounting plate
on which the pick-up
sensor is mounted back and forth.
Fixing screw
Adjusting screw
Sensor mounting plate
Fig. 5-801
3) Check the sensor operation while feeding
the paper. Adjust the pick-up sensor to the
correct position, and then fix it with the
screw.
4) Replace the covers and check the operation
again.