c) Feeder
2
Fig. 5-322 shows the window displayed after
selecting 'Feeder 2’ from the box menu.
In this figure, the analog values for the
document guide width sensor, document sensor,
document tray HP sensor and staple sensor (on a
one-by-one basis) are displayed. The mark for
the sensor that has detected a document will
illuminate.
However, the operation of the document
guide width sensor and staple sensor are
checked here, and the operation of the document
sensor and document tray HP sensor are
checked with the “Dcon Check".
•
Document guide width sensor
Slide the document guide and check that the
output value varies accordingly.
•
Staple sensor
Block the light path of the staple sensor and
check that the lamp illuminates.
To close the window, press the ‘Close’
button.
Fig. 5-322
Output of the document guide width sensor
Document sensor
Document tray HP sensor
Staple sensor
Summary of Contents for DR-6080
Page 4: ......
Page 22: ......
Page 182: ......
Page 188: ...1003N0 0 1 ...
Page 195: ...COPYRIGHT 2003 CANON ELECTRONICS INC CANON DR 6080 9080C FIRST EDITION OCT 2003 vii ...
Page 236: ......
Page 240: ......
Page 242: ...ix 1003N0 0 0 ...
Page 284: ...38 Chapter 3 Software Closing CapturePerfect 1 Select Exit from the File menu ...
Page 308: ......
Page 352: ...1 Imprinter for DR 6080 9080C Installation Procedure IMS Product Planning Dept ...
Page 355: ...4 3 Remove the left cover 4 screws Remove these screws x4 ...
Page 359: ...8 7 Insert it firmly to the back and fix it with 1 screw M3x6 ...
Page 366: ...15 14 Replace the cable to cable clamp and the document eject cover to the original position ...