Measurements
Input Voltage:
±(1% of r15 mV)
Battery Voltage:
±(2% of r15 mV)
Load Current
d
:
±(2% of r2 mA)
Battery Current
d
:
±(2% of r10 mA)
Charger Temperature:
± 2 °C
Quiescent Current
No Charge Source Present:
300 μA maximum
No Battery Connected:
Typical 5 mA at 40 VDC
Compliance:
View
the
EU
Declaration
of
Conformity
at
a
VRLA battery manufacturers state that “heat kills batteries” and recommend operating batteries at temperatures
below 50 °C.
b
Battery voltages below 8.7 V may result in <3.0 A current limit because of fold-back current limit.
c
Two-step temperature compensated constant-voltage charging for valve-regulated lead-acid batteries. Cycle and
float charging voltage parameters are programmable with the default values listed.
d
Impulse-type changes in current may have an average current measurement error of ±(10% of r 2 mA).
Table 5-1: Available Campbell Scientific battery packs
Battery Pack Model
Amp-Hour Capacity
(Ah)
Operating
Temperature Range
1
(ºC)
Battery Family
BP7
7
Charge: –15 to 50
Discharge: –20 to 60
EnerSys/Genesis
BP12
12
Charge: –15 to 50
Discharge: –20 to 60
EnerSys/Genesis
BP24
24
Charge: –15 to 50
Discharge: –20 to 60
EnerSys/Genesis
BP84
84
–40 to 71
Concorde Sun Xtender
1
Battery specifications are from the manufacturer. The CH201 contains charging algorithms that optimize battery
charging over the range of –40 to 60 °C. Battery usage outside of manufacturer specifications could have unknown
effects on the life of the battery.
CH201 12V Charging Regulator
7
Summary of Contents for CH201
Page 1: ...06 2020 Copyright 2020 Campbell Scientific CSL I D 1352 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ...Appendix A Downloading an operating system 31 Table of Contents ii ...
Page 42: ...FIGURE A 1 Downloading a new operating system CH201 12V Charging Regulator 32 ...
Page 43: ......