voltage than the solar panel. The solar power will be the primary supply and AC will be the
secondary supply if the solar panel has a higher output voltage than the AC-to-DC source.
The
12V
output
terminals
are
for
powering
a
data
logger
and
peripherals.
A
toggle
switch
controls
power
to
these
output
terminals.
The
total
output
current
is
limited
by
a
4.6 A
solid-state
circuit
breaker.
Each
battery
family
uses
a
unique
charging
algorithm
to
calculate
the
best
charging
voltage
for
battery
temperature.
The
algorithms
use
the
charger
temperature
as
the
default
temperature
source.
If
the
charger
and
battery
are
in
the
same
enclosure,
the
two
temperatures
will
be
similar.
If
the
battery
will
be
in
a
separate
enclosure,
place
a
temperature
sensor
on
or
near
the
battery
and
use
the
appropriate
SDI-12
or
RS-232
command
to
send
this
temperature
to
the
module
(see
and
27)).
The
CH201
has
two
LED
indicators,
the
CHG
(charge)
LED
and
the
CK BAT
(check
battery)
LED.
and
list
the
conditions
and
associated
colo
u
rs
for
the
CHG
and
CK BAT
LEDs.
The
CH201
communicates
using
a
data
logger
or
computer
COM
port.
Data
logger
communications
can
be
done
using
SDI-12
or
RS-232
as
indicated
in
and
26).
See
for
details.
4.1
Communications
interface
The
CH201
can
send
data
to
the
user
to
observe
and
manage
power
requirements
and
possible
problems.
It
can
also
be
configured
to
work
with
a
wide
range
of
batteries
and
input
power
supplies
and
test
the
existing
battery
system
for
possible
shorting
and
sulfation
problems.
The
CH201
can
be
used
without
any
configuration
or
communications.
To
take
advantage
of
the
additional
features
of
the
CH201,
however,
the
CH201
supports
three
kinds
of
communications:
l
Communications
to
a
computer
running
Device
Configuration
Utility.
This
utility
simplifies
configuration
of
the
CH201
and
allows
for
operating
system
updates.
Device
Configuration
Utility
may
be
downloaded
free
of
charge
at
.
See
12).
l
SDI-12 communications as an SDI-12 sensor according to the SDI-12 standard
(
). See
(p. 23) for an in depth explanation.
l
RS-232 communications to a data logger or computer. See
for an in-depth explanation.
SDI-12 data logger programming is usually simpler than RS-232 programming. Also, multiple
SDI-12 sensors can share a single data logger control or universal terminal if they have unique
CH201 12V Charging Regulator
5
Summary of Contents for CH201
Page 1: ...06 2020 Copyright 2020 Campbell Scientific CSL I D 1352 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ...Appendix A Downloading an operating system 31 Table of Contents ii ...
Page 42: ...FIGURE A 1 Downloading a new operating system CH201 12V Charging Regulator 32 ...
Page 43: ......