7.3.2.1 RS-232 commands
An RS-232 host initiates communication by sending an ASCII command string CH201(n)x
terminated with <CR> (carriage return, 0x0D in hexadecimal format), where n = command
number and x = command value.
The CH201 response string begins with an asterisk (*), followed by the comma-delimited data
strings and a checksum <CRC>. The string is terminated with <CR><LF> (carriage return 0x13,
line feed 0x10). Responses are numerical values with decimal points except for Charge State and
Charge Source, which appear as ASCII strings.
Table 7-6: RS-232 commands and responses
RS-232 command and response
Description
Command:
CH201(0)0<CR>
Response:
*,
nnnn
,
nnnn
,…,<CRC><CR><LF>
Where
nnnn
= comma-delimited values and
strings
Read CH201 status.
Values Returned:
Battery voltage, battery current, load current, DC In 1
voltage, DC In 2 voltage, temperature, target battery
voltage, maximum power input voltage setting, battery
capacity, Qloss, charge state, charge source, check
battery
Command:
CH201(1)
nn.nn
<CR>
Where
nn.nn
= temperature in °C
Response:
*Battery Temperature =
nnnn
,<CRC><CR><LF>
Where
nnnn
= set temperature
Overrides
the
internal
temperature
measurement
for
15
minutes
(or
until
cancel
l
ed
by
a
temperature
restore
command).
Useful
for
entering
the
temperature
of
a
remote
battery.
Temperature
range
is
–40.00
to
100.00 °C.
Command:
CH201(2)0<CR>
Response:
*OK<CRC><CR><LF>
Restore temperature measurement to internal CH201
measurement.
CH201 12V Charging Regulator
27
Summary of Contents for CH201
Page 1: ...06 2020 Copyright 2020 Campbell Scientific CSL I D 1352 ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ...Appendix A Downloading an operating system 31 Table of Contents ii ...
Page 42: ...FIGURE A 1 Downloading a new operating system CH201 12V Charging Regulator 32 ...
Page 43: ......