Installation

LOCATION

It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F.

A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.

 

Do not locate the 

 compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.

GROUNDING INSTRUCTIONS

1.  This product is for use on a 

nominal 120 volt circuit and has 
a grounding plug that looks like 
the plug illustrated in Figure 4. 
Make sure the product is connected 
to an outlet having the same 
confi guration as the plug. This 
product must be grounded. In 
the event of an electrical short 
circuit, grounding reduces risk of 
electrical shock by providing an 
escape wire for electric current. This 
product is equipped with a cord 
having a grounding wire with an 
appropriate grounding plug. Plug 
must be plugged into an outlet that 
is properly installed and grounded 
in accordance with all local codes 
and ordinances.

 Improper 

  use of 

grounding plug can result in 
a possible risk of electrical 
shock!

 

Do not use a 

  grounding adapter 

with this product!

2.  If repair or replacement of cord or 

plug is necessary, do not connect 
grounding wire to either fl at blade 
terminal. The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire.

 Never 

connect 

 green (or green and 

yellow) wire to a live terminal.

3.  Check with a qualifi ed electrician 

or serviceman if grounding 
instructions are not completely 
understood, or if in doubt as 
to whether product is properly 
grounded. Do not modify plug 
provided; if it will not fi t outlet, 
have proper outlet installed by a 
qualifi ed electrician.

 Overheating, 

short 

 circuiting and fi re 

damage will result from inadequate 
wiring.

LUBRICATION

This is an oilless product and 

DOES 

NOT

 require lubrication to operate.

Pre-Operation

 

BEFORE FIRST START-UP
BREAK-IN PROCEDURE

(Complete this procedure before 
using compressor for the first time. 
Once completed, it is not necessary to 
repeat.)

1.  Turn regulator knob fully clockwise 

(to the right) to open air fl ow.

2. 

Do not

 attach a hose or any other 

fi tting to the compressor.

3. Turn 

ON

 / 

OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.

5. Turn 

ON

 / 

OFF

 switch to 

ON

 position 

and run compressor for 30 minutes.

6. Turn 

ON

 / 

OFF

 switch to 

OFF

 

position.

7.  Unplug power cord.

The compressor is now ready for use.

BEFORE EACH START-UP
OPERATING PROCEDURE

1.  Turn regulator knob fully 

counterclockwise (to the left) to 
close air fl ow. 

2.  Connect air hose to outlet of 

regulator.

3. Turn 

ON

 / 

OFF

 switch to 

OFF

 

position.

4.  Plug in power cord.

5. Turn 

ON

 / 

OFF

 switch to 

ON

 position 

and let compressor run until it 
reaches automatic shutoff pressure.

6.  Attach tire chuck or tool to end of 

hose.

7.  Turn regulator knob clockwise (to 

the right) to desired pressure of 
tool being used.

 

Operation

 START-UP

 

Do not attach air 

 tools to open end of 

the hose until start-up is completed and 
the unit checks OK.

ON / OFF CYCLING OF COMPRESSOR

In the 

ON

 / 

AUTO

 position, the 

compressor pumps air into the tank. 
When a shut-off (preset “cut-out”) 
pressure is reached, the compressor 
automatically shuts off.

If the compressor is left in the 

ON

 / 

AUTO

 position and air is depleted 

from the tank by use of a tire chuck, 
tool, etc., the compressor will restart 
automatically at its preset “cut-in” 
pressure. When a tool is being used 
continuously, the compressor will cycle 
on and off automatically. 

In the 

OFF

 position, the pressure switch 

cannot function and the compressor 
will not operate. Make sure switch 
is in 

OFF

 position when connecting 

or disconnecting power cord from 
electrical outlet.

PRESSURE GAUGES

Gauge attached to regulator indicates 
air pressure going to hose (and any 
tool attached to end of hose).

Gauge attached to pressure switch 
indicates air pressure in tank.

Figure 4 - Grounding Method

Grounded

Outlet

Grounding

Pin

Minimum Gauge of Extension Cords

Length of Cord

25 feet

50 feet

100 feet

Gauge

14

12

10

4

www.campbellhausfeld.com

Operating Instructions and Parts List

FP1995 Series

Summary of Contents for FP1995 Series

Page 1: ...THE PRODUCT TO THE RETAILER Do not operate unit if damaged during shipping handling or use Damage may result in bursting and cause injury or property damage Warning indicates a potentially hazardous...

Page 2: ...from bursting See compressor specification decal for maximum operating pressure Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure 12 Never attempt to a...

Page 3: ...o resume work This compressor is equipped with an overload protector which will shut off motor if it becomes overloaded If the overload protector is actuated the motor must be allowed to cool down for...

Page 4: ...Operation BEFORE FIRST START UP BREAK IN PROCEDURE Complete this procedure before using compressor for the first time Once completed it is not necessary to repeat 1 Turn regulator knob fully clockwise...

Page 5: ...s Figure 5 OVERLOAD PROTECTOR This compressor is equipped with a thermal overload protector which will shut off motor if it becomes overloaded If overload protector shuts motor OFF frequently look for...

Page 6: ...ace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads and reassemble 4...

Page 7: ...Rear shroud 1 17 Pump motor 1 18 Cooling fan 1 19 Bracket rubber pad 4 20 Motor rubber pad 3 21 Screw M3 x 15 2 22 Hex screw 4 23 Nut M5 4 24 Screw 1 25 Wire clip 1 26 Exhaust tube FP202839AV 1 27 En...

Page 8: ...intain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or any failure caused by installing or operating unit u...

Page 9: ...sures Attention indique une situation potentiellement dangereuse qui si elle n est pas vit e PEUT mener des blessures mineures ou mod r es Avis indique de l information importante qui pourrait endomma...

Page 10: ...qui ne d passe pas 862 kPa doit tre install e dans le r servoir de ce compresseur La soupape de s ret doit avoir un d bit d air et une classification de pression suffisants pour prot ger les pi ces p...

Page 11: ...position d arr t OFF puis d brancher l appareil Patienter 30 minutes avant de rebrancher l appareil et de le remettre en marche en pla ant l interrupteur sur la position ON Ce compresseur est dot d u...

Page 12: ...re termin e avant d utiliser le compresseur pour la premi re fois Ensuite il n est pas n cessaire de la refaire 1 Tourner le bouton du r gulateur compl tement vers la droite dans le sens des aiguilles...

Page 13: ...e graissage NETTOYAGE Mettre hors circuit OFF et nettoyer la poussi re et la salet du couvercle de la pompe du r servoir et des canalisations d air SECTION DE PROTECTEUR DE SURCHARGE Ce compresseur es...

Page 14: ...vec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban tuyau pour les filets et remonter 4 Fuite du r servoir 4 V rifier le r servoir pour les...

Page 15: ...34AV 1 14 Passe fil de caoutchouc N A 1 15 Couvercle avant 1 16 Couvercle arri re 1 17 Pompe moteur 1 18 Ventilateur de refroidissement 1 19 Tampon en caoutchouc du support 4 20 Tampon en caoutchouc d...

Page 16: ...mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un montage ou fonctionnement du mod le sous des cond...

Page 17: ...ue si no se evita PODR A ocasionar la muerte o lesiones graves Precauci n indica una situaci n potencialmente peligrosa que si no se evita PUEDE dar como resultado lesiones leves o moderadas Aviso ind...

Page 18: ...terior del compresor limpio sin aceite solvente o exceso de grasa DEBE instalarle una v lvula de seguridad que est dise ada para presiones m ximas de 8 62 bar en el tanque de este compresor Esta v lvu...

Page 19: ...ente en la posici n de encendido ON para continuar con el trabajo Este compresor est equipado con un protector de sobrecarga que apagar el motor si ste se sobrecarga Si se activa el protector de sobre...

Page 20: ...iento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la perilla del regulador totalmente hacia la derecha para abrir el flujo de aire 2 No conecte una m...

Page 21: ...DRENAJE DEL TANQUE Apague el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque para drenarle toda la humedad LUBRICACION Este compresor no requiere lubricac...

Page 22: ...xiones flojas en los accesorios tuber a etc 3 Revise todas las conexiones con una soluci n de agua y jab n Si detecta una fuga 1 ajuste o 2 retire las conexiones y aplique cinta para tuber as en las r...

Page 23: ...1 14 Ojal de goma N A 1 15 Cubierta frontal 1 16 Cubierta posterior 1 17 Bomba motor 1 18 Ventilador de enfriamiento 1 19 Apoyo de goma para soporte 4 20 Apoyo de goma para motor 3 21 Tornillo M3 x 1...

Page 24: ...tc F Art culos adicionales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contraria...

Reviews: