Prior to installation, the clamping system has to be adapted to the panel thickness P :
➔
Calculate the main rod length as :
X = Panel P [+Spacer]
–
50
[mm]
Place the clamping bar
with stop bars
between
the flats of the stops:
Position spacers at a slight
vertical offset from the
cutout
Align spacer center approx.
with center of the cutout
Adaptation Steps
PLEASE NOTE:
Read the full instruction prior to installation.
•
Determine length for main rod
, see formula and schematic above.
•
Loosen positioning nuts
and compression nuts
.
•
Set main rod
to length X and block with positioning nuts
.
•
Set and block compression nuts
to a spring height of approx. 10 mm.
•
Loosen stop rod nuts
•
Set stop rods
to approx. 20 mm shorter than the main rod
’s
square end and lock nuts
•
If necessary (due to available space), cut excess rod length
16
M10
Spacer
NO
NO
=
=