20
INSTALLATION
INST
ALLA
TION
#415-R1
8-15-18 - JR
wires as follows:
1. Run the two servo cables into the control box and attach them to the servo drive. One
cable plugs in, the other attaches to screws on the front of the drive. Match the labels on
the wires with the labels on the drive. You may need to detach the ends from the cables
briefly to get them inside of the control box. Be certain to reassemble the cable ends
exactly as they were.
2. Connect the wires to the terminal strips located in the bottom right hand corner of the
control box. Follow the diagram at the right and connect the wires to the terminal strips.
Power Connection
Wire 208-240V, 3 phase power to the disconnect switch on the left hand side of the control
box. This power should be protected with 20A FRN, LPN, or equivalent fuses. Run the
incoming ground to the chassis of the control box, not to the disconnect switch. In order
to ensure that your machine is free from electrical noise, you should ground your machine
independently from other machinery. Contact your electrician if necessary.
Turn on the power and air and start the machine by depressing the green button on the
Operator Controls. Also press the power button on the computer. Make sure that the air
pressure regulator is set in the range between 60 psi and 80 psi.
Check Motor Rotation
Select "Inputs and Outputs" from the "Diagnostics" menu on the computer. Press the 5
key while in the diagnostics screen and the roller feed motor should run. The roller should
rotate in the proper direction to feed a board into the rip saw. On machines with infeed
chains, use the selector switch on the top of the control box to briefly run the chains. If
either of these motors run in the wrong direction, remove power from the machine and
swap any two of the black wires connected to the terminal strip from the motor.
Movable Saw Connection (Optional)
Mereen-Johnson 312 "Select-A-Rip":
With power disconnected from the saw, mount the "Digi-One" (included) inside of the
Mereen-Johnson control box. Attach the power cable for the "Digi-One" to the 24VDC
power supply inside of the MJ Control Box. The wire with the white stripe should attach
to the positive (+) terminal and the all black wire should attach to the negative (-) terminal.
The Digi-One has been configured at the factory with the proper baud rate to communicate
with the saw. It has been set to communicate with the Opti-Rip using IP Address:
10.0.0.78. Run an ethernet cable (included) from the extra port on the back of the Opti-Rip
Summary of Contents for Opti-Rip 415A-M1
Page 5: ...5 INTRODUCTION INTRODUCTION INTRODUCTION ...
Page 9: ...9 RULES FOR SAFE OPERATION RULES FOR SAFE OPERATION 415 R1 RULES FOR SAFE OPERATION ...
Page 14: ...14 INSTALLATION INSTALLATION 415 R1 8 15 18 JR INSTALLATION ...
Page 25: ...25 OPERATION OPERATION 415 R1 8 15 18 JR OPERATION ...
Page 46: ...46 OPERATION OPERATION 415 R1 8 15 18 JR ...
Page 56: ...56 TROUBLESHOOTING TROUBLESHOOTING 415 R1 8 15 18 JR TROUBLESHOOTING ...
Page 63: ...63 MAINTENANCE MAINTENANCE 415 R1 8 15 18 JR MAINTENANCE ...
Page 66: ...66 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR PARTS SERVICE ...
Page 69: ...69 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR ...
Page 70: ...70 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR ...
Page 71: ...71 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR ...
Page 72: ...72 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR ...
Page 73: ...73 PARTS SERVICE PARTS SERVICE 415 R1 8 15 18 JR ...