P
age
5
- Manual
FA01876-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Description
801QA-0060
ZLX24SA - Multifunction control panel, with 230 VAC power supply, for 24 V swing gates with two leaves, with graphic
programming display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN, 4 safety
inputs and memory space for up to 1000 users.
801QA-0080
ZLX24SR - Multifunction control panel, with 120 VAC power supply, for 24 V swing gates with two leaves, with graphic
programming display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN, 4 safety
inputs and memory space for up to 1000 users.
Technical data
MODELS
ZLX24SA
ZLX24SR
Power supply (V - 50/60 Hz)
230 AC
120 AC
Motor power supply (V)
36 DC
36 DC
Board power supply (V)
26 AC
26 AC
Standby consumption (W)
3
3
Power (W)
360
360
Transformer thermal protection (°C)
120
120
Colour
RAL 7040
RAL 7040
Operating temperature (°C)
-20 ÷ +55
-20 ÷ +55
Storage temperature (°C)*
-25 ÷ +70
-25 ÷ +70
Cycles/hour
20
20
Consecutive cycles
20
20
Protection rating (IP)
54
54
Insulation class
I
I
Average life (cycles)**
100.000
100.000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very
high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage, installation and maintenance
conditions. It is also infl uenced by other factors, such as climatic and environmental conditions.
Fuse table
MODELS
ZLX24SA
ZLX24SR
Line fuse
3.15 A F
4 A F
Control-board fuse
1.6 A T
1.6 A T
Accessory fuse
1.6 A F
1.6 A F