P
age
42
- Manual
FA01876-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Photocell BUS <n>
Associate a function with the photocell BUS <n> input.
<n> is between 1 and 8 and corresponds to the address set on the photocell dip-switch
The function only appears if there is a BUS photocell connected.
Confi guration>
BUS Devices
BUS Photocell 1
Photocell BUS 2
Photocell BUS 3
Photocell BUS 4
Photocell BUS 5
Photocell BUS 6
Photocell BUS 7
Photocell BUS 8
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C13 = Reopen while closing, with immediate stop once
the obstruction has been removed, even if the gate is not
in motion
Open
Close
BUS <n> key selector
Associate a function with the input BUS <n> key selector. Diff erent functions can be set according to the key turning direction.
<n> is between 1 and 7 and corresponds to the address set on the key selector dip switch
The function only appears if there is a BUS key selector connected.
Confi guration>
BUS Devices
BUS 1 key selector
BUS 2 key selector
BUS 3 key selector
BUS 4 key selector
BUS 5 key selector
BUS 6 key selector
BUS 7 key selector
Key to the right
Key to the left
Choose the command to associate with the key movement.
Open
Close
Partial opening
Stop
B1-B2 output
BUS 1 module relay - Activate output 2 (relay output) on
BUS 1 I/O module
BUS 2 module relay - Activate output 2 (relay output) on
BUS 2 I/O module
Step-by-step - The fi rst command is to open and the
second to close.
Sequential - The fi rst command is to open, the second to
STOP, the third to close and the fourth to STOP.