P
age
36
- Manual
FA01876-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Motor power
Setting power range of motors connected on M1 and M2.
The parameter is used only with generic motors. [Motor type] function set to [Generic].
Confi guration>
Motor settings
Motor power
Minimum power [up to 120W]
Medium power (Default) [up to 200W]
Maximum power [more than 200W]
Confi gure motor M1
Modify certain parameters previously described for motor M1 only (where diff erent from M2).
The function only appears with M1+M2 selected under [Number of motors].
Confi guration>
Motor settings
Confi gure motor M1
Motor type
Encoder
Limit-switch function
Input type FC/FA
Reduce speed
Motor power
See the specifi c parameters for each function.
Confi gure motor M2
Modify certain parameters previously described for motor M2 only (where diff erent from M1).
The function only appears with M1+M2 selected under [Number of motors].
Confi guration>
Motor settings
Confi gure motor M2
Motor type
Encoder
Limit-switch function
Input type FC/FA
Reduce speed
Motor power
See the specifi c parameters for each function.
Opening speed
Set the opening speed for both motors (percentage of maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Opening speed
40% to 100% (Default 70%)
Closing speed
Set the closing speed for both motors (percentage of maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Closing speed
40% to 100% (Default 70%)