I/O module <n> - Inputs
Associate a function to the I/O module <n> inputs.
<n> is between 1 and 2 and corresponds to the address set on the module dip switch.
The function only appears if there is a BUS I/O module connected.
Confi guration>
BUS Devices>
I/O module 1
I/O module 2
input I1
input I2
Deactivated (Default)
Stop = Stop the gate and exclude automatic closing. Use a
control device to resume movement.
r7 = Reopen while closing (sensitive edge with 8K2 resistor)
r8 = Reclose while opening (sensitive edge with 8K2
resistor)
Partial opening
Open
Close
Step-by-step - The fi rst command is to open and the
second to close.
Sequential - The fi rst command is to open, the second to
STOP, the third to close and the fourth to STOP.
I/O module <n> - Light output
Associate a function to the I/O module <n> input 1.
<n> is between 1 and 2 and corresponds to the address set on the module dip switch.
The function only appears if there is a BUS I/O module connected.
Confi guration>
BUS Devices>
I/O module 1
I/O module 2
Relay output
Passage-open warning light - It notifi es the user of the
operator status.
Cycle lamp - The lamp stays on during the manoeuvre.
Courtesy light - The light switches on when a manoeuvre
starts and remains on once the manoeuvre has fi nished, for
the time set under the [Courtesy time] function.
I/O module <n> - Relay output
Associate a function to the I/O module <n> input 2.
<n> is between 1 and 2 and corresponds to the address set on the module dip switch.
The function only appears if there is a BUS I/O module connected.
Confi guration>
BUS Devices>
I/O module 1
I/O module 2
Light output
Bistable
Monostable - on from 1 to 180 seconds (Default 1)