P
age
14
- Manual
FA01876-EN
- 07/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
2
Power supply output for accessories
The output normally delivers 24 V AC.
The output delivers 24 V DC (10+, 11-) when the batteries start operating, if they are installed.
3
Electric lock or electromagnets 12 V AC/DC - max 15 W.
10 11 E E3 5
M1 N1 ENC1 EB1+VB
R1
M2 N2 ENC2 EB2+VB
R2
Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Output
Power supply (V)
Maximum power
(W)
Accessories
10 - 11
26 AC
20
Additional light
10 - E3
26 AC
10
Flashing beacon
10 - E
26 AC
10
Operator status warning light
10 - 5
26 AC
3
The outputs deliver 24 V DC when the batteries start operating, if they are installed.
Device
Output
Power supply (V)
Power (W)
Auxiliary contact
B1 - B2
-
24 (24V AC/DC)
BUS CXN
BUS
15 DC
15
Do not connect anything other than CAME BUS accessories.