ASSOCIATING OUTPUTS
Associating the same output to several events or several areas (failures, alarms, etc ) gives the output the OR function
Example: if the general alarm of all the areas status is associated with the same stable output, the output will be activated when at least
one area is in alarm mode
ASSOCIATING 15
OUTPUTS
*
OUTPUT PER AREA
▲
AREA OUTPUTS 01
AREA 001
▼
*
▼
▲
▼
▲
AREA.GEN.ALR. 01
NO
+ -
▼
▲
AREA SABOTAG. 01
NO
+ -
AREA TECH ALR 01
OUTPUT 004
+ -
AREA BURG ALR 01
NO
+ -
AREA READY 01
NO
+ -
AREA ON 01
OUTPUT 002
+ -
AREA BUZZER OUTPUT 01
NO
+ -
AREA TC OUTP. 01
NO
+ -
+ -
SYSTEM FAILURE
OUTPUT 003
+ -
BATTERY FAILURE
OUTPUT 003
+ -
POWER FAILURE
OUTPUT 003
▼
▲
AREA OFF 01
NO
+ -
Area general alarm output: (Default:
NO
)
S
A
Lets you select the output to associate with the single area's general alarm
Area sabotage alarm output: (Default:
NO
)
S
A
Lets you select the output to associate with the single area's sabotage alarm (tamper
inputs and 24-hour inputs)
Area technical alarm output: (Default:
OUTPUT 004
)
S
A
Lets you select the output to associate with the single area's technical alarm (technical
inputs)
Area burglary alarm output: (Default:
NO
)
S
A
For selecting the output to associate with the single area's burglary alarm (burglary
inputs)
Area ready output: (Default:
NO
)
S
A
Lets you select the output to associate with the ready status of the single area (an area
is ready when it has no associated input open)
Area general alarm output: (Default:
OUTPUT 002
)
S
A
Lets you select the output to associate with the single area's on/off status
Area off output: (Default:
NO
)
S
A
Lets you select the output to associate with the single area's "area disarmed" status
Area buzzer output: (Default:
NO
)
S
A
Lets you select the output to associate with the single area's "buzzer input" status (the
buzzer function can be associated with an input)
Area TC output: (Default:
OUTPUT 001
)
S
A
Lets you select the output to associate with the single area's TC status
The TC output is to block the sensors with the system disarmed Its operation is as
follows (example for output no 1 of a control unit that when ON yields 13 8 V DC):
• with area off it is at 13 8 V;
• with area on and during exit time it has open output
System failure output (generic failure notification):
(Default:
OUTPUT 003
)
S
A
Lets you select the output to associate with the system failure status
Battery failure output: (Default:
NO
)
S
A
Lets you select the output to associate with the battery failure status (control unit)
230 V AC power down output: (Default:
NO
)
S
A
Lets you select the output to associate with the no grid power supply (230 V AC) status