ENGLISH

Technical menu

ACCESSING TECHNICAL MENU

Depending on the parameter 

TECH MENU ACCESS

 (

CODES

 -> 

INSTALLER'S TECHNICAL CODE

), access to the technical 

menu may or may not be preceded by the User code 

Simultaneous access from more than one keypad to the technical or user menu is not permitted 

INDIRECT ACCESS

To access the Technical Menu hold down the 

/ESC # key for 5 secs, enter the user code 

123456

, hold down the 

/ESC # key 

again for 5 secs and enter the technical code 

222222

  Using keys 

+

 

-

 

 you can move from character to character, while with keys 

    

you can change the text 

5 sec

1

+

123456

2

 

+

222222

3

5 sec

+

4  

222222

DIRECT ACCESS

With the system totally off, press key 

/ESC # for 5 seconds and enter the technical code 

222222

 to go into the Technical Menu  

Using keys 

+

 

-

 

 you can move from character to character, while with keys 

    

you can change the text 

 

5 sec

1

+

2  

222222

PROGRAMMING MODES

For the security alarm control unit to be as user-friendly as possible (for inexperienced installers as well as the most demanding profession-
als), the system incorporates the "programming mode" concept  This can provide a few or a lot of programming parameters depending on 
the installer's skill or requirements 

08:23   16/05/10

ENTER CODE

123456

WAITING

*=USER MENU

222222

PROGR. 01

MODE

PROGR. MODE

EASY

SOME PARAMETERS

WILL BE LOST!!

ARE YOU SURE?

A=YES #=ESC

*

 

*

 

 

+ - 

 

 

 

Programming modes: (Default 

EASY

)                                              

F

 

S

 

A

EASY

   only basic parameters for simple systems are available 

STANDARD

 the parameters for standard simple systems are available 

ADVANCED

 all configurable parameters are available 

When making the move from "ADVANCED" to "EASY", the keypad suggests how to do so 
Press “A” to confirm the automatic re-configuration of the parameters not managed at 
default value 
Press “#” to quit without editing the value, so it simply disappears 

MENU HEADINGS BELONGING TO THE THREE MODES

This manual shows all the menu headings as if you were in ADVANCED mode 
To find out which mode a menu heading can be displayed and therefore changed in, just look at which letters are given in the top right 
corner of the description of each heading 

 

F

 

S

 

A

Heading  present  in  all  three  modes              

 

S

 

A

 

Heading  present  in  standard  and  advanced                  

   

A

 

Heading present only in advanced

Below are the main differences between the three types:

Summary of Contents for PXC08

Page 1: ...SECURITY ALARM CONTROL UNIT PROGRAMMING MANUAL PXC08 FA00458 EN...

Page 2: ...PXLAN PXWEB 6 SCENARIOS 7 AREAS 8 KEYPADS 9 READERS 10 INPUTS 11 OUTPUTS 16 TIMES 18 TELEPHONE NOTIFICATIONS 19 TELEPHONE NOTIFICATIONS 20 ASSOCIATING OUTPUTS 22 CODES 23 KEYS 25 PHONES 26 TELEPHONE O...

Page 3: ...riendly as possible for inexperienced installers as well as the most demanding profession als the system incorporates the programming mode concept This can provide a few or a lot of programming parame...

Page 4: ...sors microwave when system is off associated with the BED ROOM area Yields a positive with BEDROOM area off U3 Failure yields a negative when failures are de tected U2 System status yields a negative...

Page 5: ...ds Default F S A The keypads used must be activated using the keys Example if you intend to use 4 keypads on the system set Readers Default F S A The readers used must be activated using the keys Exam...

Page 6: ...est F S A The test allows you to manually control the system s outputs Inputs test F S A The test allows you to control the status of the system s inputs RS485 BUS SYSTEM 02 RS485 BUS RS485 SPEED 9600...

Page 7: ...sed for arming some specific areas for example a scenario that only arms the perimeter area PERIMETER ON SEL AREAS OFF Only the selected areas are disarmed nothing changes with the status of the areas...

Page 8: ...leave the system with some areas unarmed because some inputs are open In this case the triggering of the alarm will inevitably warn that the system has been left with inputs open Slave Default A The d...

Page 9: ...areas Scenario 3 CLOSE SHOP SEL AREAS ON areas Keypad 1 Situated in the home associated areas scenario A CLOSE HOME scenario B OPEN HOME scenario C CLOSE SHOP Keypad2 Situatedintheshop associatedarea...

Page 10: ...reas scenario L1 CLOSE HOME Reader 2 Situated in the shop associated areas scenario L1 CLOSE SHOP Code 1 Owner associated areas Code 2 Employee associated areas Scenarios Default L1 sc 1 L2 sc 2 L3 sc...

Page 11: ...AILURE It is active whether the control unit is armed or disarmed In the event of an alarm the failure LED comes on the system failure output is activated and the ANOMALY message is displayed on the c...

Page 12: ...e associated areas switch off Pulse on off When an input is unbalanced the associated areas switch status when they are off they switch on and when on they switch off Stable arm disarm When an input i...

Page 13: ...PARTIAL ON the input is delayed if all the associated areas are on and is delayed if it is partialised at least one area off and one on Example this parameter is set when you need to have the front d...

Page 14: ...set using the keys Example two sensors are aimed on the same room and the user wants an alarm to be sig nalled only when both sensors go into alarm mode Input 1 Type IMMEDIATE And input INPUT 2 Input...

Page 15: ...f the input is deactivated or no area associated with it is armed the output is commanded by the status of the input To be more precise the output is activated if the input is unbalanced and reset if...

Page 16: ...of which can be selected Parameter visible only if the output is the pulse type Activation duration Default 000 S A Duration time of pulse output activation Activation duration Example you want to op...

Page 17: ...with POSITIVE SECURITY the relay will normally be energised and will de energise only when the output is activated Remote activation Default NO S A If activated YES it lets you remotely activate the...

Page 18: ...after replacing the battery carry out a manual BATTERY TEST by accessing the technical menu Power down notification delay Default 060 S A This determines after what period the LACK of GRID voltage is...

Page 19: ...numbers with the keys Activating and restoring the control unit and bus peripherals sabotage alarm A Telephone notifications associated with the activation and restoration of the control unit s sabot...

Page 20: ...of the system total arming means the total arming of the areas managed Set the telephone numbers with the keys Arming and disarming single areas A Telephone notifications associated with arming and di...

Page 21: ...Set the telephone numbers with the keys Entering key S A Telephone notifications associated with entering the key on the reader With select the keys Set the telephone numbers with the keys Activating...

Page 22: ...glary alarm output Default NO S A For selecting the output to associate with the single area s burglary alarm burglary inputs Area ready output Default NO S A Lets you select the output to associate w...

Page 23: ...s only allowed when the control unit is totally off no area on AFTER USER CODE Programming the control unit from PC is only allowed when the control unit is totally off no area on and the User code ha...

Page 24: ...user code to access the user menu Activating user menu heading Armings Default ENABLED A Enables the User Code to access the heading Armings on the User Menu Activating user menu heading Events Defau...

Page 25: ...ou want to use a key it must be activated Areas associated with the key Default S A Lets you assign the areas of competence of the key Use the keys to set the areas to be associated Key learning F S A...

Page 26: ...ted to a switchboard with GSM call option 0 C 0 4 5 6 7 8 9 0 1 2 Telephone number Indicates the presence of the switchboard Number to request line from switchboard Telephone communication format Defa...

Page 27: ...keypad a code key associated with the areas of competence that has the property of disarming areas NONE If an event general technical sabotage etc alarm starts the cycle of telephone calls it CANNOT b...

Page 28: ...he remote control by GSM and safe GSM you can select the telephone numbers the telephone dialler must answer Activating PSTN line control Default NO A If activated it checks control of the PSTN line I...

Page 29: ...ch off PREVIOUS STATUS The on off status of the areas goes back to the one preceding Reboot C U Quick arming Default DISABLED A If activated it lets you start scenarios from the keypads without having...

Page 30: ...d correctly they can give rise to unwanted interventions of the control unit PROGRAMMER 22 PROGRAMME A MODIF ESC PROG AT STEP 01 NEW ESC PROG AT STEP 01 HRS 00 PROG AT STEP 01 MINUTES 00 PROG AT STEP...

Page 31: ...See User Manual for displaying events Events print out A Press to start printing out the events on the control unit RS 232 CLOCK TIME DATE 25 14 34 05 07 10 A EDIT NO 03 46 01 01 10 YEAR 10 03 46 01...

Page 32: ...OU SURE A YES ESC ARE YOU SURE A YES ESC ARE YOU SURE A YES ESC RESTORE CODES IN PROCESS RESTORE KEYS IN PROCESS A A A The default parameters do not delete the acquired codes and keys To do that you h...

Page 33: ...ld still be faulty contacts X AREA ALARM xx AREA ALRM RST xx AREA DESCR When an input goes into alarm mode so do the associated areas X INP ALARM xxx RESTORE INPUT xxx INPUT DESCR Input xxx has gone i...

Page 34: ...YSTEM FAIL RST SYST FAIL Generic system failure notification The failure might be caused by batteries 230V power supply power supply unit or fuses X SYST TEC ALRM RST SYS T ALR Generic technical alarm...

Page 35: ...a message received notification or notification of receipt of the KISS OFF package OUTPUT ON XXX Activating an output OUTPUT OFF XXX Deactivating an output PSTN DOWN PSTN RESTORED When the line has b...

Page 36: ...Italy 33079 Sesto al Reghena Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English Manual code FA00458 EN ver 1 04 2017 CAME S p a The data and information shown in this manu...

Reviews: