Page
10
- Manual:
FA00458-EN
- vers.
1
- 04/2017 - © C
AME S.p.A. - The data and information shown in this manual ar
e t
o be consider
ed as subject t
o change at any time and without the need for any advance warning.
ENGLISH
READERS
INSERTERS 06
*
MODIFY INSERT. 01
INSERTER 01
▲
ASSOC. AREAS 01
####
▼
*
▼
▲
▼
▲
+ -
SCENARIO L2 01
GOING TO BED
+ -
SCENARIO L1 01
GOING OUT
+ -
SCENARIO L3 01
STAYING INDOORS
+ -
▼
▲
ENTRY BUZZER 01
YES
TAMPER 01
NO
EXIT BUZZER 01
YES
ALARM BUZZER 01
YES
DESCRIPTION 01
INSERTER 01
+ -
+ -
+ -
+ -
*
Associated areas: (Default:
#-
)
S
A
Associated areas are the areas which can be managed by the reader These also represent
an AND-type filter on the areas managed by the code and scenario
Example: there is a flat above a ground-floor shop The owner wants to be able to manage
the flat and the shop with the same key
Area 1 = HOME
Area 2 = SHOP
Scenario 1 = CLOSE HOME (
SEL.AREAS ON
; areas =
#-
)
Scenario 2 = CLOSE SHOP (
SEL.AREAS ON
; areas =
-#
)
Reader 1 = Situated in the home: (associated areas =
#-
; scenario L1 =
CLOSE HOME
)
Reader 2 = Situated in the shop: (associated areas =
-#
; scenario L1 =
CLOSE SHOP
)
Code 1 = Owner (associated areas =
##
)
Code 2 = Employee (associated areas =
-#
)
Scenarios: (Default:
L1=sc.1; L2=sc.2, L3=sc.3
)
S
A
Associate the scenarios with the three reader LEDs
With the
+
–
keys modify the scenario associated with the reader LED
Example: a home has three areas (living-room, bedroom and perimeter) that you want to
manage via two activations: total, perimeter only
Area 1 = LIVING AREA
Area 2 = BEDROOM AREA
Area 3 = PERIMETER
Scenario 1 = GOING OUT (
EXACT ON+OFF
; areas =
###
)
Scenario 2 = STAYING INDOORS (
EXACT ON+OFF
; areas =
--#
)
Reader 1 = (associated areas =
###
; scenario L1 =
GOING OUT
; scenario L2 =
STAYING INDOORS
; scenario L3 =
NO SCENARIO
)
Tamper: (Default:
NO
)
S
A
Lets you enable/disable the warning of no communication with readers
Entry buzzer: (Default:
YES
)
S
A
Lets you enable/disable the buzzer during entry time
Exit buzzer: (Default:
YES
)
S
A
Lets you enable/disable the buzzer during exit time
Alarm buzzer: (Default:
YES
)
S
A
Lets you enable/disable the buzzer during control unit alarm time
Reader description:
S
A
Lets you edit the description of the reader