10 -
119RF86 ver. 1 05/2014
English
DESCRIPTION
001SIRCEWL is an outdoor curtain-effect passive infrared radio
sensor, with adjustable support (up to 190°), with anti-masking
and ant-removal tamper features. The device is fitted with two
IR sensors that work on AND logic, that is, the alarm is triggered
only when both sensors detect and intrusion.
Precautions
WARNING: the device works on lithium batteries. Handle
with care.
Danger of explosion and fire. Do not throw out the batteries
into a fire. Do not heat of damage the batteries. Respect the
marked polarities. To replace the batteries contact a SKILLED
TECHNICIAN. Dispose of exhausted batteries in compliance
with the laws in effect, even when decomissioning the
device. If any liquid comes out, protect your hands with
special gloves.
Technical data
Type
001SIRCEWL
Powered by 2 3 [V] lithium batteries
CR123A
Draw when standing by [uA]
60
Draw while in alarm state [mA]
50
Estimated effectiveness [years]*
2
DUAL-BAND radio transmission frequency
[MHz]
868.65/433.92
IR Coverage [m]
5x1
IR Range [m]
2–5
Detectable speed [m/s]
0.3 – 1.5
Sensitivity [°C]
2.0 (at 0.6 m/s)
Stabilizing time after powering on [s]
120
Operating temperature [°C]
-20 / +60 °
Max. environmental humidity [%]
95 %
Sensor's container dimensions [mm]
155x35x42.5
Power supply and interface module container
dimensions [mm]
155x35x42.5
Protection rating [IP]
55
Weight [g]
215
*The sensor's battery life duration is inversely proportional to the
number or detections it is subjected to (regardless of whether the
alarm system is armed or not).
If the sensor is installed in high frequency transit zones, the
battery life may be drastically shortened.
Features
A
LED
Meaning
Indications
Initiation
Flashes for about 120 seconds.NOTE. In this
phase the LED flashes even if DIP4 is set to OFF
Alarm
Stays on for two seconds
Antimasking
detection
Flashes three times before repeating the
sequence.
Dipswitch
DEFAULT
DIP1 (Walk test)
ON
The LED turns on in case of detection regardless of of
the DIP4 setting. The DIP2 setting is irrelevant.
OFF
The LED turns on in case of detection only if it is
enabled, that is, depending on the DIP 4 setting. The
minimum interval between subsequent detections
depends on the DIP2 setting.
DIP2 (Minimun interval between subsequent detections)
ON
Five second interval
OFF
120 second interval
NOTE. The sensor does not trigger an alarm at intervals that are
smaller than the given time.
DIP3 (ALARM and TROUBLE outputs)
ON
NO outputs
OFF
NC outputs
For the system to work properly, the outputs must be set to
NC mode (DIP3 OFF)
DIP4 (LED)
ON
enabled
OFF
disabled
If the LED turns on even though DIP4 is OFF, check the setting
of DIP1 (walk test)
DIP5 (PIR sensitivity)
ON
Normal sensitivity
OFF
Low sensitivity
DIP6 (Anti-masking)
ON
Anti-masking active
Summary of Contents for 001SIRCEWL
Page 1: ...001SIRCEWL RU Fran ais FR English EN Italiano IT 119RF86...
Page 2: ...A 0 8 1 2 m Tilt ON ON 1 2 3 4 5 6 C D B CN6 REMOVE CN3 2 119RF86 ver 1 05 2014...
Page 4: ...1 3 2 1 3 2 Wiring 2 1 L O J M K N a a a a a 4 119RF86 ver 1 05 2014...
Page 6: ...100 mm 0 8 1 2 m 83 5 mm V W X Y 6 119RF86 ver 1 05 2014...
Page 19: ...19 119RF86 ver 1 05 2014...