Chapter 3: Operation
Radio Recovery
Page
3-92
Use below procedure to enter in default mode manually.
Procedure 28 Default mode
1
Insert the override plug into the RJ-11 GPS utility port of the module.
2
Power cycle by removing, then re-inserting, the Ethernet cable.
RESULT: The module boots with the default IP address of 169.254.1.1, password fields
blank, and all other configuration values as previously set.
3
Wait approximately 30 seconds for the boot to complete.
4
Remove the override plug.
5
Set passwords and IP address as desired.
6
Change configuration values if desired.
7
Click the Save Changes button.
8
Click the Reboot button.