Chapter 1: Configuration
General configuration
Page
1-86
Attribute
Meaning
Timing Mode
Allows the user to choose the mode between Timing Master and Timing
Slave.
Link Speed
From the drop-down list of options, select the type of link speed for the
Ethernet connection. The default for this parameter is that all speeds are
selected. The recommended setting is a single speed selection for all BHMs
and BHSs in the operator network.
802.3at Type 2 PoE
Status and
PoE Classification
When the PoE Classification functionality is enabled and if Type 2
power is not present, the PAs do not power up and draw too much
power.
By default, the PoE Classification feature is disabled and the PAs will
power up regardless of the classification presented by the power
source.
This is supported only on 450i Series ODUs.
PoE Classification configuration status also can be check under home
> General > Device Information tab:
Region
This parameter allows you to set the region in which the radio will operate.
The BHS radio automatically inherits the Region type of the master. This
behavior ignores the value of the Region parameter in the BHS, even when
the value is None. Nevertheless, since future system software releases may
read the value in order to configure some other region-sensitive feature(s),
this parameter must be always set to the value that corresponds to the local
region.
Country
This parameter allows you to set the country in which the radio will operate.
The BHS radio automatically inherits the Country Code type of the master.
This behavior ignores the value of the Country parameter in the BHS, even
when the value is None. Nevertheless, since future system software releases
may read the value in order to configure some other region-sensitive
feature(s), this parameter must be always set to the value that corresponds
to the local region.
PMP/PTP 450i Series ODU shipped to the United States is locked to a
Region Code setting of “United States”. Units shipped to regions other than
the United States must be configured with the corresponding Region Code
to comply with local regulatory requirements.
Webpage Auto
Update
See
Table 22 General page attributes – PMP 450i AP
Bridge Entry Timeout
Specify the appropriate bridge timeout for correct network operation with
the existing network infrastructure. Timeout occurs when the BHM
encounters no activity with the BHS (whose MAC address is the bridge
entry) within the interval that this parameter specifies. The Bridge Entry
Timeout must be a longer period than the ARP (Address Resolution
Protocol) cache timeout of the router that feeds the network.
Summary of Contents for PMP 450 AP
Page 51: ...Chapter 1 Configuration Quick link setup Page 1 23 ...
Page 155: ...Chapter 1 Configuration Configuring security Page 1 127 ...
Page 163: ...Chapter 1 Configuration Configuring security Page 1 135 ...
Page 164: ...Chapter 1 Configuration Configuring security Page 1 136 ...
Page 193: ...Chapter 1 Configuration Configuring radio parameters Page 1 165 ...
Page 194: ...Chapter 1 Configuration Configuring radio parameters Page 1 166 ...
Page 195: ...Chapter 1 Configuration Configuring radio parameters Page 1 167 ...
Page 206: ...Chapter 1 Configuration Configuring radio parameters Page 1 178 ...
Page 210: ...Chapter 1 Configuration Configuring radio parameters Page 1 182 ...
Page 636: ...Chapter 5 Troubleshooting Logs Page 5 16 Figure 95 SM Authorization log ...