Chapter 3: Operation
System information
Page
3-6
Registered SM Count
This field indicates how many SMs are registered to the AP.
Sync Pulse Status
This field indicates the status of synchronization as follows:
Generating Sync indicates that the module is set to
generate
the sync pulse.
Receiving Sync indicates that the module is set to
receive
a sync pulse from
an outside source and is receiving the pulse.
No Sync Since Boot up / ERROR: No Sync Pulse indicates that the module
is set to
receive
a sync pulse from an outside source and is not receiving the
pulse.
Note
When this message is displayed, the AP transmitter is turned
off to avoid self-interference within the system.
Sync Pulse Source
This field indicates the status of the synchronization source:
Searching indicates that the unit is searching for a GPS fix
Timing Port/UGPS indicates that the module is receiving sync via the timing
AUX/SYNC timing port
Power Port indicates that the module is receiving sync via the power port
(Ethernet port).
On-board GPS indicates that the module is receiving sync via the unit’s
internal GPS module
Maximum Count of
Registered SMs
This field displays the largest number of SMs that have been simultaneously
registered in the AP since it was last rebooted. This count can provide some
insight into sector history and provide comparison between current and
maximum SM counts at a glance.
Data Slots Down
This field indicates the number of frame slots that are designated for use by
data traffic in the downlink (sent from the AP to the SM). The AP calculates
the number of data slots based on the Max Range, Downlink Data and
(reserved) Contention Slots configured by the operator.
Data Slots Up
This field indicates the number of frame slots that are designated for use by
data traffic in the uplink (sent from the SM to the AP). The AP calculates the
number of data slots based on the Max Range, Downlink Data and (reserved)
Contention Slots configured by the operator.
Contention Slots
This field indicates the number of (reserved) Contention Slots configured by
the operator. See
on page
Connection Status
This field indicates the device connectivity to cnMaestro (Cambium’s cloud-
based network management system).
Account ID
This field shows Account ID which is registered with Cambium Networks and
it allows operator to manage devices using cnMaestro.
Summary of Contents for PMP 450 AP
Page 51: ...Chapter 1 Configuration Quick link setup Page 1 23 ...
Page 155: ...Chapter 1 Configuration Configuring security Page 1 127 ...
Page 163: ...Chapter 1 Configuration Configuring security Page 1 135 ...
Page 164: ...Chapter 1 Configuration Configuring security Page 1 136 ...
Page 193: ...Chapter 1 Configuration Configuring radio parameters Page 1 165 ...
Page 194: ...Chapter 1 Configuration Configuring radio parameters Page 1 166 ...
Page 195: ...Chapter 1 Configuration Configuring radio parameters Page 1 167 ...
Page 206: ...Chapter 1 Configuration Configuring radio parameters Page 1 178 ...
Page 210: ...Chapter 1 Configuration Configuring radio parameters Page 1 182 ...
Page 636: ...Chapter 5 Troubleshooting Logs Page 5 16 Figure 95 SM Authorization log ...