Chapter 1: Product description
Overview of the 450 Platform Family
Page
1-5
PMP: Up to 120 mi (or 193 km) for 900 MHz band
Duplexing
TDD (symmetric and asymmetric)
Connectivity
1000Base-T Ethernet Main port with PoE input
Operating
frequencies
902 to 928 MHz
3.3 to 3.9 GHz
4.9 to 5.925 GHz
Tx Power -
conducted
Max 25 dBm (3 GHz)
Max 27 dBm (5 GHz)
Max 25 dBm (900 MHz)
Channel
bandwidth
5, 7, 10, 15, 20, 30, and 40 MHz
Note
All bands do not support all channel bandwidths. For more
information, refer to this
Spectral
efficiency
Up to 7.5 bps/Hz
Timing
synchronization
CMM4, CMM5, or UGPS
Data rate
Up to 310 Mbps (40 MHz channel BW) for PMP/PTP
Frequency bands
The PMP/PTP 450i Series ODU can operate in the following bands:
•
900 MHz band: 902 to 928 MHz
•
3 GHz band: 3300 to 3900 MHz
•
5 GHz band: 4900 to 5925 MHz
Note
900 MHz, 3 GHz, and 5 GHz bands with different frequencies require different hardware
components.
Hardware components
The ODU (Outdoor unit) is a self-contained transceiver unit that houses both radio and networking
electronics. The main hardware components of the PMP/PTP 450i Series are as follows:
•
PMP 450i AP
•
PMP 450i SM
•
PTP 450i BH (BHM/BHS)