Chapter 5: Installation
Mount the ODU, LPU and surge suppressor
Page
11
2
Using the included (depending on pole diameter):
•
M8 x 70mm hex cap bolts (2 quantity)
or
•
M8 x 40mm hex cap bolts (2 quantity)
and
•
M8 flat washers (2 quantity)
•
M8 coil washers (2 quantity)
Attach the mounting bracket to the pole/mast. The
mounting bracket is designed to attach to poles with
diameters in the range of 2 in. (50mm) to 3in.
(75mm).
3
Complete the AP mounting assembly by attaching
the included:
•
8mm hex cap bolt (one quantity)
Through the AP’s attached mounting bracket and
pole mount. Now the AP may be adjusted to the
desired position and tightened with a 1/2-inch
spanner wrench to 11 lb/ft (14Nm).
PMP 450 SM (except PMP 450 SM - 900 MHz)
1
Use stainless steel hose clamps for the attachment.
2
Attach the mounting bracket to the structure.
Tighten the locking nut.
PMP 450 SM 900 MHz (connectorized)
The PMP 450 900 MHz connectorized SM mounting procedure is different from other radios. It does not
get directly mounted on pole.