Chapter 5: Installation
Installing ODU
Page
65
15
Launch your web browser. In the URL address bar, enter 169.254.1.1. then press Enter.
16
If the browser in laptop fails to access the interface of the SM, follow the procedure
on page
17
Log in as admin on the ODU. Configure a password for the admin account and log off.
18
Log back into the SM as admin or root, using the password that you configured.
19
For coarse alignment of the SM, use the Alignment Tool located at Tools, Alignment
Tool.
Optionally, connect a headset to the AUX/SYNC port on the SM and listen to the
alignment tone, which indicates greater SM receive signal power by pitch. By adjusting
the SM’s position until the highest frequency pitch is obtained operators and installers
can be confident that the SM is properly positioned. For information on device GUI tools
available for alignment, see sections Using the Alignment Tool, Using the Link
Capacity Test tool, and Using AP Evaluation tool in Configuration Guide.
20
When the highest power is achieved, lock the SM mounting bracket in place.
21
Log off of the SM web interface.
22
Disconnect the Ethernet cable from your laptop.
23
Replace the base cover of the SM.
24
Connect the Ethernet cable to the computer that the subscriber will be using.
Installing a 450 Platform Family BHM
To install a 450 Platform Family BHM, perform the following steps.
Procedure 7 Installing a BHM
1
Choose the best mounting location for your particular application.
2
Align the BHM as follows:
a.
Move the module to where the link will be unobstructed by the radio horizon and no
objects penetrate the Fresnel zone.
b.
Use a local map, compass, and/or GPS device as needed to determine the direction
to the BHS.
c.
Apply the appropriate degree of downward or upward tilt.
d.
Ensure that the BHS is within the beam coverage area.
3
Using stainless steel hose clamps or equivalent fasteners, lock the BHM into position.
See
Installing external antennas to a connectorized ODU
for connecting
external antenna
4
If this BHM will not be connected to a CMM, optionally connect a cable to a GPS timing