SECTION 4: FLOW
®
making
since 1986
water work
Note:
The two settings that must be set are the K
value and the Offset. If you know these values enter
them now. If not, Call Calsense at 1-(800)-572-8608
for assistance.
The ranges for these two settings are:
•
K:
0.200 to 800.00
•
OFFSET:
0.000 to 1.000
4B.2 Regular flow meter setup
If the answer to Use your own K & Offset is NO.
1.
Press the blue
ARROW
keys to move
the cursor to the FLOW METER SIZE:
setting.
2.
Press the
PLUS
or
MINUS
keys to
change the flow meter type.
Refer to the chart (Figure 4.8), to choose the correct
flow meter type.
MODEL NUMBER
SIZE
FM-1
FM-1B
FM-1.25B
FM-1.5
FM-1.5B
FM-2
FM-2B
FM-3
1” PLASTIC FLOW METER
1” BRASS FLOW METER
1 ¼” BRASS FLOW METER
1 ½” PLASTIC FLOW METER
1 ½” BRASS FLOW METER
2” PLASTIC FLOW METER
2” BRASS FLOW METER
3” PLASTIC FLOW METER
Figure 4.8
THIS CONCLUDES THE POC (MV & FM)
SECTION
4C. LEARN EXPECTEDS
The Learn Expecteds option on the controller will
allow the controller to learn the expected flow rate
for each station It is only available if a flow meter is
in use.
From the MAIN MENU screen:
1.
Press the
FLOW
Menu key.
The FLOW METER, MASTER VALVE & PUMP
screen is displayed (Figure 4.9).
Pump On-at-a-Time
Learn Expecteds Mainline Capacity
Alert Actions Flow Checking
FLOW METER, MASTER VALVE & PUMP
& Valve Close Times
Line Fill Flow Meter
Figure 4.9
2.
Press the
LEARN EXPECTEDS
Menu key (Figure 4.9).
The LEARN THE EXPECTED FLOW RATES screen
is displayed (Figure 4.10).
PROG A . . . . . . . . . . . . . . . . . . . . NO
Learn The Expected Flow Rates for:
DRIP 1 . . . . . . . . . . . . . . . . . . . . NO
LEARN THE EXPECTED FLOW RATES
each station and use the measured flow
to set the expected flow rate.
At the next program start, turn on
DRIP 2 . . . . . . . . . . . . . . . . . . . . NO
PROG B . . . . . . . . . . . . . . . . . . . . NO
PROG C . . . . . . . . . . . . . . . . . . . . NO
PROG D . . . . . . . . . . . . . . . . . . . . NO
PROG E . . . . . . . . . . . . . . . . . . . . NO
Figure 4.10
•
LEARN EXPECTEDS:
Setting a value to
YES will allow the controller to learn the
expected flow rate for each station at the
next program start. Once the flow rate has
been recorded the entry on the screen will
default back to NO.
3.
Press the
PLUS
or
MINUS
keys
to select the program.
4.
Press the blue
ARROW
keys to
change the setting.
THIS CONCLUDES THE LEARN EXPECTED
SECTION