1. GENERAL INFORMATION

Before using the product carefully read the information 

contained in this instruction manual, the manual should 

be kept for future reference.

Italian is the original language of this instruction

manual, this language is the reference language in 

case of discrepancies in the translations.

This manual is part of the essential safety requirement

and  must  be  retained  until  the  product  is  finally  de-

commissioned.

The customer, in case of loss, can request a copy

of the manual by contacting Calpeda S.p.A. or their 

agent, specifying the type of product data shown on 

the label of the machine (see 2.3 Marking)

Any changes, alterations or modifications made to the

product or part of it, not authorized by the manufacturer, 

will revoke the “CE declaration” and warranty.

This appliance should not be operated 

by children younger than 8 years, 

people with reduced physical, sensory 

or mental capacities, or inexperienced 

people who are not familiar with the 

product, unless they are given close 

supervision or instructions on how to 

use it safely and are made aware by a 

responsible person of the dangers its 

use might entail.

Children must not play with the 

appliance.

It is the user's responsibility to clean 

and maintain the appliance. Children 

should never clean or maintain it 

unless they are given supervision.

Do not use in ponds, tanks or 

swimming pools or where people may 

enter or come into contact with the 

water.

Read carefully the installation 

section which sets forth:

 

The maximum  permissible

structural  working pressure

(chapter 3.1).

-  

The type and section of the

power cable (chapter 6.5).

-  The type of electrical protection

to be installed (chapter 6.5).

1.1. Symbols

To improve the understanding of the manual, below are 

indicated the symbols used with the related meaning.

 

 

Information and warnings that must be 

observed, otherwise there is a risk that the 

machine could damage or compromise 

personnel safety.

The failure to observe electrical information 

and warnings, could damage the machine or 

compromise personnel safety.

i

  Notes and warnings for the correct management 

of the machine and its parts.

   Operations that could be performed by the final 

user. After carefully reading of the instructions, 

is responsible for maintenance under normal 

conditions. They are authorized to affect 

standard maintenance operations.

Operations that must be performed by a 

qualified  electrician.  Specialized  technician 

authorised to affect all electrical operations 

including maintenance. They are able to 

operate with in the presence of high voltages.

  Operations that must be done performed by 

a  qualified  technician.  Specialized  technician 

able to install the device, under normal 

conditions, working during “maintenance”, 

and allowed to do electrical and mechanical 

interventions for maintenance. They must 

be capable of executing simple electrical 

and mechanical operations related to the 

maintenance of the device.

 Indicates that it is mandatory to use individual 

protection devices.

OFF

  Operations that must be done with the device 

switched off and disconnected from the power 

supply.

ON

  Operations that must be done with the device 

switched on.

SUMMARY

1.

GENERAL INFORMATION .............................8

2.

TECHNICAL DESCRIPTION ..........................9

3.

TECHNICAL FEATURES ................................9

4.

SAFETY ..........................................................9

5.  TRANSPORTATION AND HANDLING .........10

6.

INSTALLATION .............................................10

7.

STARTUP AND OPERATION ....................... 11

8.

MAINTENANCE ............................................ 11

9.

DISPOSAL ....................................................12

10. SPARE PARTS .............................................12

11. ESIGNATION OF PARTS .............................12

12. TROUBLESHOOTING ..................................13

Drawing for dismantling and assembly ..................62

Declaration of conformity .......................................64

Summary of Contents for CT Series

Page 1: ...Page English P gina Espa ol...

Page 2: ...d section of the power cable chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with...

Page 3: ...e of the device is forbidden as is use under conditions other than those indicated in these instructions Improper use of the product reduces the safety and the efficiency of the device Calpeda shall n...

Page 4: ...e technical catalogue 6 2 Ambient requirements and installation site dimensions The customer has to prepare the installation site in order to guarantee the right installation and in order to fulfill t...

Page 5: ...st starting OFF ATTENTION never run the pump dry Start the pump after filling it completely with liquid When the pump is located above the water level suction lift operation or with a positive suction...

Page 6: ...ves before dismantling For dismantling and re assembly see construction in the cross section drawing To remove the impeller 28 00 T TP use the threaded dismantling holes 9 DISPOSAL OFF The final dispo...

Page 7: ...ary replace it See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of...

Page 8: ...que se instalar el Cap tulo 6 5 1 1 S mbolos utilizados Para mejorar la comprensi n se utilizan los s mbolos pictogramas a continuaci n con sus significados Informaci n y advertencias que deben respet...

Page 9: ...ise ado y fabricado exclusivamente para el uso descrito en el p r 2 1 Est totalmente prohibida la utilizaci n del dispositivo para usos impropios y que no est n indicados en este manual El uso impropi...

Page 10: ...e ser golpeado Hay que evitar la superposici n al embalado de otro material que podr a da ar la bomba Si el peso supera los 25 Kg el embalado tiene que ser levantado por dos personas al mismo tiempo 6...

Page 11: ...s y para 220 240 50Hz con termoprotector incorporado 7 ARRANQUE Y USO 7 1 Controles antes del arranque La bomba no debe funcionar en presencia de parte deteriorada 7 2 Primer arranque OFF ATENCI N Evi...

Page 12: ...r que el rodete no esta bloqueado por incrustaciones o por otras causas Limpiar eventualmente con adecuada precauci n 8 2 Desmontaje del sistema Antes del desmontaje cierre las compuertas en aspiraci...

Page 13: ...aci n c Limpiar el filtro si es necesario sustituirlo Ver tambi n el punto 2a 4 Caudal insuficiente a Tuber a y accesorios con di metro demasiado peque o que provocan excesivas perdidas de carga b Pre...

Page 14: ...g and assembly Dibujo para desmontaje y montaje 98 04 46 00 28 00 76 00 14 00 14 04 28 20 76 04 94 00 76 54 98 00 82 00 88 00 82 04 82 08 81 00 81 08 78 00 73 12 73 00 36 00 14 20 36 52 36 50 90 00 14...

Page 15: ...00 92 00 46 00 70 18 36 50 14 12 12 20 81 00 82 04 94 02 76 04 94 00 76 54 98 00 98 08 14 00 98 04 70 00 14 04 82 00 90 00 88 00 3 94 112 28 20 28 00 12 00 14 20 3 94 114 14 00 14 24 14 24 32 00 14 1...

Page 16: ...40 2009 DECLARACION DE CONFORMIDAD En CALPEDA S p A declaramos bajo nuestra exclusiva responsabilidad que las Bombas CT T TP B I M modelo y numero de serie marcados en la placa de caracteristicas son...

Reviews: