The ELAN Properties Screen
BRIM-A6DP User’s Guide
3-15
6. Ensure that the MAX MTU Size field displays [1516]. If it does not,
press the SPACE bar until [1516] displays.
7. Use the arrow keys to highlight the LES ATM Address field.
8. Enter the LES ATM Address. Ensure that a valid ATM Address is
used.
9. Use the arrow keys to highlight the ADD/MODIFY command at the
bottom of the screen and press ENTER. The manually configured LEC
is now entered into the BRIM-A6DP LEC Index. Check the ELAN
Properties screen to verify that the ELAN became operational. For
information on the ELAN Properties screen proceed to Section 3.7.
3.7
THE ELAN PROPERTIES SCREEN
To access the ELAN Properties screen from the ATM Setup screen,
perform the following steps:
1. Use the arrow keys to highlight the ELAN Properties selection of the
ATM Setup screen.
2. Press ENTER; the ELAN Properties screen, Figure 3-5, displays.
Figure 3-5
The ELAN Properties Screen
ESX-1320 Local Management
Flash Image Version: XX.XX.XX
LEC PROPERTIES
RETURN
EXIT
NEXT
LEC Index:
LEC ID:
d
3
LEC STATE:
STATUS:
operational(7)
active(1)
LEC ATM ADDR:
LECS ATM ADDR:
LES ATM ADDR:
BUS ATM ADDR:
0000000000000000000000000000000000000000
0000000000000000000000000000000000000000
0000000000000000000000000000000000000000
0000000000000000000000000000000000000000
LECS Configuration Direct VCC:
LES Control Direct VCC:
LES Control Distribute VCC:
BUS Multicast Send VCC:
BUS Multicast Forward VCC:
:
0, 0
0, 40
0,255
0, 41
0,253
PREV
Summary of Contents for BRIM-A6DP
Page 1: ...BRIM A6DP USER S GUIDE ...
Page 2: ......
Page 14: ...Chapter 1 Introduction 1 6 BRIM A6DP User s Guide ...
Page 22: ...Chapter 2 Installation 2 8 BRIM A6DP User s Guide ...
Page 64: ...Appendix A APIM Specifications A 8 BRIM A6DP User s Guide ...
Page 66: ...Appendix B BRIM A6DP Specifications B 2 BRIM A6DP User s Guide ...