Chapter 2: Installation
2-6
BRIM-A6DP User’s Guide
11. Reinstall the faceplate mounting screws and the standoff screws.
12. Reinstall the MIM in the MMAC.
13. Reattach all MMAC power cords.
14. Reattach the network cabling to the MIM.
15. Refer to Chapter 3 for instructions on configuring the BRIM-A6DP
using Local Management.
2.3.2
Installing a BRIM in a Hub
To install a BRIM-A6DP into a standalone hub that supports BRIM
technology perform the following steps:
1. Power down the hub and remove the power cord.
2. Disconnect all cables from the hub. Note the ports to which these
cables attach.
3. Attach the disposable grounding strap to your wrist (refer to the
instructions outlined on the disposable grounding strap package).
4. Remove the hub chassis cover (refer to your specific hub
documentation for instructions on removing the hub chassis cover).
5. Remove the faceplate mounting screws and the BRIM coverplate.
See Figure 2-2.
6. Remove the standoff screws. See Figure 2-2.
7. Place the BRIM behind the hub faceplate. See Figure 2-3.
8. Insert the connector pins of the BRIM into the BRIM connector on the
hub.
9. Press down firmly on the back of the BRIM until the pins slide all the
way into the connector holes.
Ensure that you remove the power cord and ONLY the screws
required to remove the chassis cover. Failure to comply could
result in an electric shock hazard.
Summary of Contents for BRIM-A6DP
Page 1: ...BRIM A6DP USER S GUIDE ...
Page 2: ......
Page 14: ...Chapter 1 Introduction 1 6 BRIM A6DP User s Guide ...
Page 22: ...Chapter 2 Installation 2 8 BRIM A6DP User s Guide ...
Page 64: ...Appendix A APIM Specifications A 8 BRIM A6DP User s Guide ...
Page 66: ...Appendix B BRIM A6DP Specifications B 2 BRIM A6DP User s Guide ...