1.
Exit the User Notation Table by pressing ESC twice. The system prompt will appear.
2.
Type ED, and press ENTER. The last three lines should be as shown below:
ED
EDIT (W, U)
3.
To edit the Wire List, press W. (Do not press ENTER.) The monitor should display two
additional lines as shown below:
ED
EDIT (W, U)
EDIT Wire List
W 0001
NOTE
The editor is in the Cursor Positioning mode when it is first entered.
The left column indicates which table is being edited and the current
mode. The Cursor Positioning mode is denoted in the Wire List Table
when only a W is displayed as shown above. The Replace mode is
indicated with an RW while the Add mode (Insert) is indicated by an
AW.
4.
The Wire List Table may contain previous data. To initialize the list, type I and press
ENTER. Type Y to the prompt "
Initialize
?"
WARNING:
Verify that you are in the Wire List Table before entering the Initialize
command. Inside the Editor the Initialize command is used to clear the
Wire List or User Notation Tables. Outside the Editor, from the
system prompt, Initialize is also used to format floppy diskettes.