64
cab - Produkttechnik GmbH & Co KG / Tharo Systems, Inc.
Heat Level
The parameter "Heat level" enables the printer to adapt to possible differences
in the thermal properties of different printheads.
The parameter scale is from -9 to +9.
A previous adjustment has already been carried out in the factory.
In the event of replacing the printhead, the setting possibly has to be adjusted.
NOTICE !
To adjust the printer to current print jobs, it is recommended that you
alter the heat level parameter via software. (e.g. for different material and
speed)
Any front panel value and software command value are totaled together for
printing.
The current field to be changed is flashing in the display.
Fig. 9 i Set "Heat level" parameter
Heat level
+ x
Heat level
- x
Heat level
± 9
Heat level
± 0
*
*
*
Heat level
± x
Yes
Heat level
± x
No
Confirmation
Sign (+ or -)
8 Heat level
9 Printer info
Heat level
7 Printhead pos.
Summary of Contents for THARO Apollo Series
Page 1: ...Edition 2 01 Transfer Printer Apollo Apollo 1 Apollo 2 Apollo 3 Operator s Manual...
Page 84: ...84 cab Produkttechnik GmbH Co KG Tharo Systems Inc This page is intentionally left blank...
Page 106: ...106 cab Produkttechnik GmbH Co KG Tharo Systems Inc This page is intentionally left blank...
Page 112: ...A 6 cab Produkttechnik GmbH Co KG Tharo Systems Inc Table A 2 b Unicode 0100 01FF...
Page 113: ...A 7 cab Produkttechnik GmbH Co KG Tharo Systems Inc Table A 2 c Unicode 2000 20FF...
Page 114: ...A 8 cab Produkttechnik GmbH Co KG Tharo Systems Inc Table A 2 d Unicode 2100 21FF...
Page 134: ...E 2 cab Produkttechnik GmbH Co KG Tharo Systems Inc This page is intentionally left blank...