3.
Install the new sensor, screwing all the way in until it makes contact with the sensor target. Roll
back and use a 0.35mm feeler gauge to set the distance. Tightening the nut in place.
4.
Congratulation you have successfully replaced the EL ST/UP limit sensor.
3.7.3. Elevation Down Sensor
1.
Raise the antenna so that the EL Down Limit Sensor lines up with a solid part of the EL Down
flag.
Elevation UP Limit
Sensor
Elevation Stow
Sensor