2019/08 - Indice de révision : D - Code : 29650
TRAITEMENT DE L'EAU
71/72
Problem
Possible cause
Solution
The device remains off, even
though it should be working
The system was turned off
Turn it on
The panel power supply has short
circuited
Check the fuse or circuit breaker on
the electrolyser panel power line
The power cable connection to the
panel is loose
Cut power to the panel, remove the
lid covering the panel connection
terminals and tighten the power
cable connections
The fuse protecting the main circuit
board has blown
Contact the after sales service for
inspection and replacement if this
proves necessary.
One or both wires in the power
cable is cut.
Inspect the cable and check
the electrical continuity using a
multimeter
The Chlorine output cannot reach
100%
It is not set at 100%
Check and correct if necessary
Electrode surfaces are dirty
(limescale, etc.)
Descale the cell
The cell is worn out after being
used for a long time
Replace the cell