2019/08 - Indice de révision : D - Code : 29650
TRAITEMENT DE L'EAU
69/72
•
Disconnect the acid suction tube from the blue connector on the pump.
•
Remove the transparent splash guard.
•
Carefully disconnect the acid injection tube from the injection nipple and allow water from the pumping
circuit to empty into a bucket placed below.
CELL
:
•
Descale and clean the cell (ref VIII.5), either using the acid dosing pump before it is winterized, or manually
after dismantling the cell (ref. X.5) ;
•
Open the bottom union to drain water from the cell, then screw the union shut ;
•
Unscrew the blue head of the flow sensor and remove it.
SENSORS:
•
Cut the power supply to the electrical/ control panel;
•
Disconnect the sensors from the electrical/ control panel;
•
Close the shut-off valve on the by-pass loop on which the sensors are mounted;
•
remove the sensors and place them in their phials of buffer solution and store them in an area protected
against freezing.
10.7
Active winterizing
Cut the power supply to the electrical/ control panel.
The various components may be left in place if suitable winterizing chemicals are added to the water to
prevent the growth of algae andfiltration is run every day.
Filtration must notably be run while the ambient temperature in the plant room where the material is
installed is +2°C or less.
ANNEXE 1 – Liste récapitula
ti
ve des messages d’aver
ti
ssement et d’erreur, et
des icônes par
ti
culières
Message
STD-BY LOW
(SALT)
HIGH
(SALT)
SHRT
CELL
NO
CELL
NO
FLOW
LOW
TEMP
HIGH
TEMP
paragraphe
VII et
XII
IX.I
IX.2
IX.1 et
2
IX.1 et
2
IX.3
IX.4
IX.4
Message
ACID
PIPE
NEED
PUMP
PH
HIGH
PH
LOW
ORP
HIGH
ORP
LOW
NO
CARD
PH
PROBE
paragraphe
IX.5
IX.6
IX.7
IX.7
IX.7
IX.7
IX.9
IX.8
Message
ORP PROBE
CELL SIZE
paragraphe
IX.8
Modèle de cellule ne correspondant pas au
modèle du co
ff
ret (80 m3 / 150 m3)
Température
d’eau supérieure
à 65°C
Concentra
ti
on en
sel supérieure à
6,5 g/l
Débit d’eau insu
ffi
sant au
passage dans le contrôleur,
fil
tra
ti
on est en route
Clavier du c
offre
t
verrouillé
Carte électronique en défaut
Mode réglage (réservé au
fabricant)
Concentra
ti
on en
sel inférieure à
3,0 g/l
Salt concentration
greater than 6.5 g/l
Salt concentration
less than 3.0 g/l
Cabinet
temperature
greater than 6.5 g/l
Keypad locked
Flow rate through the
controller insufficient, filtration
running
Circuit board defect
Parameter setting mode
(manufacturer only)