INSTALLATION & OPERATING

INSTRUCTIONS

Catalog No. 6000.554

Effective: 12-21-11

Replaces: NEW

  P/N 241460 Rev. 1         

FOR YOUR SAFETY:

Do not store or use gasoline or other flammable vapors and

liquids or other combustible materials in the vicinity of this or any other appliance. To
do so may result in an explosion or fire.

Professional Series

PS10353ti-E-HC

PS10354ti-E-HC

PS10355ti-E-HC

Heat Pump

Pool & Spa  

Heater

US

C

LISTED

R

NOTE:

The instructions in this manual are for the use of qualified individuals specially trained and experienced

in the installation and maintenance of this type of equipment and related system components. Installation and
service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a
safe place for future use.

Summary of Contents for Professional PS10353ti-E-HC

Page 1: ...C PS10355ti E HC Heat Pump Pool Spa Heater US C LISTED R NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or...

Page 2: ...2 ...

Page 3: ...M 4500 MAXIMUM 4500 MAXIMUM 4500 MAXIMUM Free Chlorine PPM 2 to 3 2 to 3 2 to 3 Total Dissolved Solids PPM 3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM Free Chlorine MUST NOT EXCEED 5 PPM In salt water chlorinated pools the total TDS can be as high as 6000ppm Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water is balanced Automatic chemical dosing d...

Page 4: ...eat Cool Operation 11 System Start Up 11 Seasonal Start Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 12 System Drain Down 12 Continuous Pump Operation 12 Maintenance 12 Air Coil Cleaning 12 Cabinet Care optional 12 Unplug Condensation Drain Holes 12 Troubleshooting 12 Service Call Verification 13 Power Supply 13 Water Flow 13 Time Clock Adjustment 14 Plumbing Diagrams 15 Wiring Diagr...

Page 5: ...nd the heat pump pool heater CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exceed 104 F 40 C A temperature of 100 F 38 C is considered safe for a healthy adult Special cau tion is suggested for young children 2 Drinking of alcoholic beverages before or during spa or hot tub use can cause dro...

Page 6: ...tion each side of the unit at least 1 ft 30 cm from walls pipes and other obstructions Recirculation of cold discharge air back into the evaporator coil will greatly reduce the unit s heat ing capacity and efficiency This unit features an up flow discharge for quiet operation Air is pulled up through the evaporator coil and discharged through the top grill Allow at least 5 ft 1 5 m clearance above...

Page 7: ...ational Electrical Code NFPA No 70 latest edition and all applicable state and local codes Wiring diagrams are located on pages 19 through 21 Locate the equipment disconnect means within 3 feet of the heater s electrical enclosure or as close to the heater as possible Always satisfy applicable codes and standards In sizing power wiring be especially aware of up sizing requirements necessary due to...

Page 8: ...8 SEE BRACKET HURRICANE TIE DOWN DWG 50 1 2 10353 10354 10355 50 1 2 50 1 2 ...

Page 9: ...ual in size to the main pool spa circulation pip ing 4 In cold weather freeze zone areas shutoff valves ball or gate type must be installed at the unit inlet and outlet to facilitate service and cold weather drain down 5 Operate the pump and check the system for leaks Pressure Drop For system pressure drop information refer to Table B below CAUTION The heat pump pool heater inlet and outlet connec...

Page 10: ...T key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA To Increase the Desired Water Temperature Pool or Spa Mode Push the SET key until you see POL or SPA The pro grammed temperature will be displayed Press the UP arrow to increase the temperature setting one degree at a time To Lower the Desired Water Temperature Pool or Spa Mode Push the SET key until you see P...

Page 11: ...fountains sprays or other water features to speed cooling NOTE Heating is more efficient during warmer day light hours and cooling is more efficient during cooler night time hours Seasonal Start Up or Annual Check 1 Remove leaves pine needles etc from the evap orator coil Clean the coil by gently applying a mild solution of household liquid soap and water 2 Gently rinse the coil with water DO NOT ...

Page 12: ...er pipes This is also evidence of heat removal from the air When the air is cool with low humidity condensation may not be evident WARNING Shut OFF electricity to the unit before cleaning Freeze Protection If the unit is installed in a location subject to freezing conditions it is important to protect the water circuit from freezing just as should be done for the pump and filter System Drain Down ...

Page 13: ...and heat pump pool heater shut OFF before the water temperature is raised to the desired level you must lengthen the running time of both To do this reset the time clock dial for the longer running time or manually operate the pump with the timer override switch Since the unit capaci ty and efficiency are both greater at higher ambient air temperatures run time should be set to take advantage of a...

Page 14: ...ne temperature sensor is open or may be defective FLO Possible causes The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of water to pool pump FIL parameter must be set to activate pool pump Water flow switch may be broken FL3 The unit has encountered 3 FLO faults within the same call for heat and shut down the unit for protection If this occurs you should c...

Page 15: ...CHECK VALVE CHEMICAL INTRODUCTION WATER OUT TO POOL OR SPA Fig 6 For systems with pumps of less than 2 HP under 80 gpm no external bypass is required Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators ...

Page 16: ...PA Fig 7 For systems with pumps of 2 HP or greater over 80 gpm an external bypass is required Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump pool heater Connections are 2 inch unions Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators 16 ...

Page 17: ...Fig 8 Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 17 ...

Page 18: ...ry Secondary BRANCH MAIN BRANCH MAIN BRANCH MAIN 15 GPM 2 2 15 GPM 2 2 15 GPM 2 2 30 2 2 30 2 2 1 2 30 2 3 45 2 2 45 2 3 45 2 4 60 2 2 1 2 60 2 3 60 2 4 80 2 3 80 2 4 80 2 5 Sizing based on 10 ft sec flow rates MINIMUM PIPE SIZES 2 UNITS 3 4 UNITS 5 6 UNITS 18 ...

Page 19: ...19 Wiring Diagram 208V 230V 3Ph 60Hz Models ...

Page 20: ...Wiring Diagram 460V 3Ph 60 Hz Models 20 ...

Page 21: ...21 Wiring Diagram 380V 3Ph 60 Hz Models ...

Page 22: ... until OFF is displayed Wait until a temperature is displayed before beginning the next step 2 Push the SET key until SPA is displayed then push the UP arrow to 104 F Wait until a tempera ture is displayed before beginning the next step 3 Push the SET key until P_S is displayed then push the DOWN arrow until POL is displayed Wait until a temperature is displayed before begin ning the next step 4 F...

Page 23: ...23 ...

Page 24: ...24 Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Heat Pump Service 1 800 260 2758 Litho in U S A ...