Maintenance and inspection
Butzbach GmbH Industrietore
Originalbedienungsanleitung SPACELITE_V1
24/02/2021
33
(e.g. VDE determinations, DIN sheets, technical rules of other member states to the European Economic Area
treaty) in order to be able to determine that the power-operated doors can be safety operated.
Examples of these people are qualified personnel of the manufacturer or delivery companies, the operator's
personnel who have been trained by the manufacturer or other people with corresponding expert knowledge.
Qualified individuals must make their assessment objectively from the perspective of occupational safety
without being influenced by other factors, such as financial.
9.2
Maintenance and Inspection Work
The system is equipped with devices that serve to ensure the safety and protection of the operating personnel
and the system. Therefore, the safety devices and components must be checked regularly.
9.2.1 Inspection of safety components
Items
Instructions
Frequency
Safety components
Main switch
Turn the switch to the ON and OFF position.
Quarterly, at least annually
Optoelectronic
sensitive edge
Simulate hitting a blunt object during closing by
pressing in on the rubber profile on the lower
door panel (at several points if possible). The
door should first stop and then reverse direction.
Monthly
Safety edge signal
(batteries in the radio
unit)
We recommend replacing the batteries for
sending the signal to the safety edge annually:
Unscrew and remove the cover. Then, change
the batteries.
Annually
Additional control unit
components
If present: check their function.
Monthly
Batteries for
emergency power
supply (HT150XL)
The system operator must ensure that the fluid
fill level of the batteries and the charge status is
checked by a qualified individual at least every
three months as well as after each movement
operation made using emergency power supply.
At least quarterly as well as after each
movement operation via the emergency
power supply
Danger! Never disable safety devices!
Never disable safety devices or bypass them.
Do not operate the system if safety devices are damaged!
Caution!
During simulation maintain a distance of at least 1 m from the moving door. Otherwise, there is the risk of
mild injuries and damage.