Assembly instructions for the motor

Before fitting the motor, the coupling must be fitted between the
motor and the vacuum pump. Please follow the installation instructions
for the coupling. Regarding the explosion protection, the coupling
must have at least the same protection class as the vacuum pump for
the outside category ("outside" (o)). Please refer to the nameplate of
the pump. A higher protection level, for example for explosion group
or temperature class, can also be used. Only genuine Busch couplings
can be used.

When fitting or replacing the drive motor observe the assembly
procedure for the coupling.

WARNING

Prior to fitting the coupling, it is imperative that the coupling ma-
nufacturer’s operating instructions are read and understood. If in
any doubt, please contact your local Busch representative or
consult the coupling manufacturer’s internet site: www.sami-
flex.com.

CAUTION

During assembly of the coupling, make sure that value E is adhered
to.

When value E is not followed, the coupling can be damaged.

CAUTION

Regarding the ATEX explosion protection, the motor must have at
least the same protection class as the vacuum pump for the outside
category ("outside" (o)) and must support the ambient temperature
at least equal to that permitted for the vacuum pump. Check the
correspondance of the motor nameplate with the vacuum pump
nameplate.

Fitting of the couplings

Description

Type

Coupling

Samiflex A4

Axial displacement

When fitting/ replacing the motor or during maintenance of the
coupling, assembly tolerances have to be respected in order to prevent
axial displacement.

l

Fit the coupling hubs onto the respective shafts of the vacuum
pump and the drive motor

l

Axially move the unit motor/ coupling hub in such a way until the
axial distance between the coupling halves = 3.5 mm (see
"COBRA ATEX catalogue")

If the unit motor/ coupling hub is already fitted:

u

Move the coupling hubs on the shafts in order to reach value E
(see "COBRA ATEX catalogue")

l

Lock the coupling hubs by tightening the set screws

u

Tightening torque: 10 Nm

Coupling alignment

The recommended radial and angular displacement/ alignment
limitations for the AC 1000 F VR pump/ coupling alignment should not
exceed 0.01 mm in any direction.

Installation

Assembly

l

Make sure that the “Installation Prerequisites” are complied with

l

Fit or install the vacuum pump at its final location

Electrical connection

WARNING

Risk of electrical shock, risk of damage to equipment.

Electrical installation work must only be executed by qualified per-
sonnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- VBG 4 or corresponding national accident prevention regulation.

CAUTION

The connection schemes given below are typical. Specific orders or
deviating connection schemes for certain markets may apply.

Risk of damage to the drive motor!

Please check drive motor connections inside the terminal box and
refer to the drive motor connection instructions.

l

Connect the drive motor electrically

l

Connect the earth line

l

Two earth connections are also available on the pump base frame,
diameter: 10.5 mm

Delta connection (Low voltage):

Star connection (High voltage):

CAUTION

Operation of the pump in the wrong direction of rotation, even for
a short period of time, can destroy the vacuum pump.

Prior to starting-up of the vacuum pump, please ensure that the va-
cuum pump is connected up correctly.

l

Determine the direction of rotation with the arrow sign on the fan
cover of the motor

l

Press the start button and hold briefly

l

Watch the fan of the drive motor and determine the direction of
rotation just before the fan stops

Installation and Commissioning

Page 11

L1

L2

L3

U1

U2

V1

V2

W1

W2

U1

U2

L1

V1

V2

L2

W1

W2

L3

U1

U2

L1

V1

V2

L2

W1

W2

L3

L1

L2

L3

U1

U2

V1

V2

W1

W2

Summary of Contents for COBRA AC 1000 F

Page 1: ...e Instructions Screw Vacuum Pumps COBRA AC 1000 F VR Vapour Recovery ATEX version II 2G i o IIB T4 X Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870561056 180809 Original instructi...

Page 2: ...First start up of the system 13 Switching off the system 13 Re start procedure following an Emergency Shut Down of the system 14 Maintenance 14 General information 14 Maintenance program 15 Weekly 15...

Page 3: ...g liquid inlet connection CLO Cooling liquid outlet connection OFP Oil filler plug OSG Oil sight glass ODV Oil drain ball valve MP Magnetic plug DV1 Ventilation G1 4 DV2 Aeration valve CLD Cooling liq...

Page 4: ...g liquid injection in the cylinder The COBRA vacuum pumps the principle of screw pumps Two parallel screws RT rotate in opposite directions in the pump body Entering gases are trapped between the pitc...

Page 5: ...l accordingly Local regulations regarding the motors and electric control elements must be observed when installing the pump in potentially explosive environments The maintenance instructions must be...

Page 6: ...careful packing Check the packaging for transport damage when the goods arrive The pump can withstand temperatures between 25 C and 55 C during transport Transportation of packaged pump Packed on a p...

Page 7: ...pe corresponds to the ambient conditions see Oil type Ambient pressure atmospheric Humidity range 20 to 95 Altitude up to 1000 m l Make sure that the cooling liquid fulfills the following require ment...

Page 8: ...scharge lines the line cross section should be larger than the exhaust flange in order to prevent a drop in the performance of the vacuum pump If you have any doubts contact your Busch representative...

Page 9: ...or PSA 0301 The sensor must be connected in such a way that the vacuum pump stops when the counter pressure reaches the value prescribed in the COBRA ATEX catalogue Technical data of the standard prod...

Page 10: ...meter FSA 0502 The contact flow meter must be connected in such a way that the vacuum pump stops when the flow drops below 2 l min It is possible to run the vacuum pump with an injection liquid flow o...

Page 11: ...talogue If the unit motor coupling hub is already fitted u Move the coupling hubs on the shafts in order to reach value E see COBRA ATEX catalogue l Lock the coupling hubs by tightening the set screws...

Page 12: ...t the cooling liquid inlet CLI and outlet CLO connections l Open the cooling liquid supply l Adjust the cooling liquid flow to 12 l min Connection of the injection liquid into the cylinder INJ NOTE Ma...

Page 13: ...e that the Installation Prerequisites are complied with and will remain so and ensure that adequate cooling is guaranteed If the pump is shut down for a longer period of time CAUTION If there is a ris...

Page 14: ...ations given below WARNING The inside of the vacuum pump must regularly be checked for de posits and be cleaned as and when necessary for example by pur ging the pump Deposits can cause friction and s...

Page 15: ...eaks have the vacuum pump repaired Busch service l Check the vacuum pump for cooling liquid leaks in case of leaks have the vacuum pump repaired Busch service In case of operation in a dusty environme...

Page 16: ...ler plugs OFP l Top up with oil l Make sure that the oil level is on MAX mark of the oil sight glass l Make sure that the seal of the oil filler plug are not damaged and replace plug if necessary l Re...

Page 17: ...ing liquid in compliance with applicable re gulations Checking the current consumption l Check the current of the motor An increased current indicates a fault see Troubleshooting Checking the motor ho...

Page 18: ...es must be disposed of separately in compliance with applicable environmental regulations When the vacuum pump comes to the end of its life it must be decontaminated CAUTION Only authorised personnel...

Page 19: ...artial clogging in the suction discharge or pressure line Remove the clogging Long suction discharge or pressure line with too small diameter Use larger diameter Internal parts worn or damaged Repair...

Page 20: ...ral weeks or months Let the vacuum pump run warm with inlet closed Oil viscosity is too high for the ambient tempe rature Use oil with a better viscosity class Improper oil quantity unsuitable oil typ...

Page 21: ...ge intervals are too long The oil was overheated Drain oil Fill in new oil see Maintenance In case the oil life is too short use oil with better heat resistance or retrofit cooling Cooling liquid flow...

Page 22: ...1 0486000766 510 O ring 2 0486511445 511 O ring 1 0486000645 512 O ring 2 0486000526 513 O ring 2 0486000636 514 O ring 2 0486000538 515 Shaft seal 1 0487553116 516 Seal 2 0486511080 732 Flat seal 1 0...

Page 23: ...ellus S2 V 68 High Performance hydraulic oil viscosity class ISO HC 68 20 60 C TOTAL AZOLLA ZS 68 viscosity class ISO VG 68 Oil quantity The quantity of oil specified in the following table is of info...

Page 24: ...l motor speed 50 Hz 60 Hz min 1 min 1 3000 3600 Noise level EN ISO 2151 50 Hz 60 Hz dB A dB A 83 85 Ambient temperature C 20 40 Ambient temperature high temperature version refer to the pump nameplate...

Page 25: ...tances to prevent hazard zones being reached by the upper and lower limbs EN 1012 1 2010 EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Part 1 and 2 EN ISO 2151 2008 Acoustics...

Page 26: ...Note...

Page 27: ...Note...

Page 28: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...

Reviews: