Table I: Boiler Ratings / Data
(1)
(2)
(3)
(4)
Boiler
Model
Horse-
Power
Gross
Output
(MBH)
Net I=B=R Rating
Burner Input
Heating
Surface
(Sq. Ft.)
New
Firebox
Volume
(Cu. Ft.)
Pressure
in Firebox
(In. Wtr.
Clmn.)
Water Content
(Gal.)
Boiler Weight
w/Water (Lbs.) Vent
Dia.
(In.)
Sq. Ft.
Steam
MBH
Steam
MBH
Water
Oil
(GPH)
Gas
(MBH) Steam Water
Steam Water Steam Water
V903A
10.3
347
1083
260
302
3.1
447
34.2
37.0
3.2
.33
44.5
66.0
1439
1618
7
V904A
14.4
483
1508
362
420
4.2
606
48.6
54.3
4.8
.38
53.0
75.0
1811
1995
7
V905A
19.3
646
2021
485
562
5.6
808
63.0
71.5
6.4
.31
61.5
84.0
2184
2372
8
V906A
24.1
808
2525
606
703
7.0
1010
77.5
88.8
7.9
.38
70.0
93.0
2557
2749
8
V907A
28.6
959
2996
719
834
8.3
1198
91.9
106.0
9.5
.36
78.5
102.0
2930
3126
8
V908A
33.2
1110
3471
833
965
9.6
1386
106.3
123.3
11.0
.35
87.0
111.0
3303
3503
10
V909A
10.1
1342
4225
1014
1167
11.6
1674
120.7
140.5
12.6
.35
95.5
120.0
3676
3880
10
V910A
45.6
1528
4867
1168
1329
13.2
1905
135.1
157.8
14.2
.40
104.0
129.0
4048
4257
10
V911A
51.2
1714
5513
1323
1490
14.8
2136
149.5
175.0
15.7
.45
112.5
138.0
4421
4634
12
V912A
56.8
1900
6142
1474
1652
16.4
2367
164.0
192.3
17.3
.49
121.0
147.0
4794
5011
12
(1) Type of Build Prefix:
K = Knockdown, A = Knockdown w/Assembled Sections, P = Packaged, F = Packaged and Firetested
Trim Suffix:
S = Steam Boiler, W = Water Boiler
Fuel Suffix:
N = Natural Gas, P = LP Gas, O = Oil, C = Natural Gas/Oil, D = LP Gas/Oil, M - Less Burner
Burner Suffix:
B = Beckett, C = Carlin, J = Power Flame JR, P = Power Flame C, W = Webster, L = Less Burner
(2)
I=B=R net ratings shown are based on piping and pick-up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for
installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping systems, etc. The burner capacity in
GPH is based on oil having a heat value of 140,000 BTU per gallon.
(3)
Firebox volume does not include added volume of 8” extended burner mounting plate (BMP). If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume
listed above.
(4)
Boiler ratings are based on 12.5% CO
2
(oil) and 9.7% CO
2
(natural gas), + .10” (inches) water column pressure at boiler flue outlet. Ratings shown above apply at
altitudes up to 1000 feet on oil and 2000 feet on gas.
For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
Safety (Relief) Valve Set Pressure:
USA Steam Boiler - 15 PSI, USA Water Boiler - 50 PSI
Optional USA Water Boiler - 30 PSI, 80 PSI (special order)
Canadian Steam Boiler - 15 PSI, Canadian Water Boiler - 45 PSI
Optional Canadian Water Boiler - 30 PSI (special order)
Summary of Contents for operating and
Page 2: ...2 ...
Page 8: ...8 Section I General Information Figure 1 Dimensional Information ...
Page 21: ...21 Figure 16 Bare Boiler Assembly ...
Page 25: ...25 Figure 22 V9A Series Jacket Assembly Boiler Models V903A thru V912A ...
Page 31: ...31 Figure 26 V9A Series Minimum Piping Parallel Water Boiler ...
Page 32: ...32 Figure 27 V9A Series Minimum Piping Primary Secondary Water Boiler ...
Page 33: ...33 Figure 28 V9A Series Minimum Piping Details Bypass with Blend Pump Water Boiler ...
Page 34: ...34 Figure 29 V9A Series Minimum Piping Primary Secondary with Bypass Water Boiler ...
Page 37: ...37 Figure 32 Minimum Piping Requirements For Gravity Return V9A Series Steam Boilers ...
Page 42: ...42 Figure 37b DHW Generation with Tankless Coils Storage Tank and Destratification Pump ...
Page 43: ...43 Figure 37c DHW Generation with Indirect Water Heater ...
Page 58: ...58 Figure 40 Bare Boiler Assembly ...
Page 62: ...62 SERVICE RECORD DATE SERVICE PERFORMED ...
Page 63: ...63 SERVICE RECORD DATE SERVICE PERFORMED ...
Page 64: ...64 ...