![Burnham MPC Installation And Operation Manual Download Page 12](http://html.mh-extra.com/html/burnham/mpc/mpc_installation-and-operation-manual_2832959012.webp)
1
Model MPC™ Boilers
Boiler Model
Boiler Horsepower
Burner Input
Gross Output (MBH)
Net I=B=R Rating
(MBH)
Combustion
Efficiency
Heating Surface
(Sq. Ft.)
Net Furnace V
olume
(Cu. Ft.)
Pressure in Firebox
(Inches Wtr
. Column)
W
ater Content
(Gallons)
Boiler W
eight
w/W
ater (LBS.)
V
ent (Flue Outlet
Damper) Dia.
(Inches)
Oil (GPH)
Oil (MBH)
Gas (MBH)
Oil - %
Gas - %
MPC4
12.7
3.55
497
500
424
369
89.0
86.3
75.0
7.1
0.10
63
2820
7
MPC5
19.5
5.50
770
773
652
567
88.8
86.1
95.3
9.1
0.19
78
3396
7
MPC6
25.0
7.10
994
995
837
728
88.7
86.0
115.5
11.0
0.28
93
3972
8
MPC7
30.6
8.70
1218
1216
1023
890
88.7
86.0
135.8
12.9
0.34
108
4558
8
MPC8
36.1
10.2
1428
1438
1209
1051
88.6
85.9
156.1
14.8
0.39
123
5144
8
MPC9
41.7
11.8
1652
1660
1395
1213
88.6
85.9
176.4
16.7
0.45
137
5721
10
MPC10
47.2
13.4
1876
1881
1580
1374
88.6
85.9
196.6
18.6
0.50
152
6307
10
MPC11
52.8
15.0
2100
2103
1766
1536
88.5
85.9
216.9
20.6
0.66
167
6893
10
MPC12
58.3
16.6
2324
2325
1951
1697
88.5
85.8
237.2
22.5
0.82
182
7489
12
MPC13
63.8
18.2
2548
2547
2137
1858
88.5
85.8
257.5
24.4
0.98
196
8077
12
MPC14
69.4
19.8
2772
2769
2322
2019
88.5
85.8
277.7
26.3
1.14
211
8673
12
MPC15
74.9
21.5
3010
2991
2508
2181
88.4
85.8
298.0
28.2
1.30
226
9269
12
MPC16
80.5
23.0
3220
3213
2694
2343
88.4
85.8
318.3
30.2
1.30
241
9865
12
MPC17
86.0
24.5
3430
3435
2880
2504
88.4
85.8
338.6
32.1
1.40
256
10470
12
MPC18
91.6
26.0
3640
3657
3065
2665
88.4
85.8
358.8
34.0
1.50
270
11068
12
(1) Suffix “N” indicates natural gas-fired, suffix “P” indicates LP gas-fired, “O” indicates oil-fired, “C” indicates combination natural
gas/oil-fired, “D” indicates combination LP gas/oil-fired.
(2) I=B=R net ratings shown are based on 1.15 piping and pickup factor for water.
Consult manufacturer for installations having unusual piping and pickup requirements, such as intermittent system operation,
extensive piping systems, etc.
(3) The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon.
(4) Boiler ratings are based on 13.2% CO
2
(oil) and 10.2% CO
2
(natural gas) and +.10” water column pressure at boiler flue
outlet.
Ratings shown above apply at altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the
ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
Safety Relief Valve Set Pressure: Standard - 50 PSI; Optional - 30 PSI, 80 PSI
TABLE II: RATINGS/DATA
(1)
(3)
(2)
(4)
Summary of Contents for MPC
Page 19: ...19 Figure 5 Manual or Hydraulic Draw up Section Assembly ...
Page 28: ...28 Table VII Modular Return Water Mixing Tube RWMT RC ...
Page 29: ...29 Figure 13 Return Water Mixing Tube RC Assembly and Installation ...
Page 78: ...78 Figure 56 MPC Common Bare Boiler Components ...
Page 80: ...80 Figure 56 MPC Common Bare Boiler Components continued ...
Page 82: ...82 Figure 57 MPC Front Center Section Frame Rail Assembly ...
Page 84: ...84 Figure 58 MPC Rear Section Frame Rail Assembly ...
Page 86: ...86 Figure 59 MPC Return Water Mixing Tube RC Assembly ...
Page 88: ...88 Figure 60 MPC Heat Exchanger Insulation Wrapper ...
Page 90: ...90 Figure 61 MPC Internal Wiring Harness Components ...
Page 92: ...92 Figure 62 MPC Jacket Panel Assembly ...
Page 94: ...94 Figure 62 MPC Jacket Panel Assembly continued ...
Page 96: ...96 Figure 63 MPC 2 nd and 3 rd Pass Flueway Baffles ...