29
Fluid installation
Type 8746 Profibus, 8746 Analogue
Tab. 21:
Stainless steel compression fittings and related seals
product inter-
nal-threaded
connections in
accordance with
din isO 228/1
pipe
diameter
article number
stainless steel
compression-fitting
seal
(1 piece)
G 1/4
6 mm
901538
901575
G 1/4
8 mm
901540
G 1/4
1/4"
901551
901579
G 1/4
3/8"
901553
G 3/8
8 mm
901542
901576
G 3/8
10 mm
901544
G 3/8
1/4''
901555
901580
G 3/8
3/8''
901556
G 1/2
10 mm
901546
901577
G 1/2
12 mm
901548
G 1/2
1/2''
901557
901581
G 1/2
3/4''
901558
G 3/4
12 mm
901549
901578
G 3/4
3/4''
901559
901582
G 1
On request
installation procedure
The procedure is given for the compression fittings
available from Bürkert.
•
If you use pipe fittings from another manufacturer, obey
the instructions from this manufacturer.
No inlet section is required.
The connection to the pipe is explained for one side of the product.
The same procedure applies on the other side of the product.
→
Remove all dirt from the pipes and from the fluid carrying
components of the installation.
→
Cut the pipe squarely [
1
] and deburr [
2
]. See Fig. 12
.
1
2
Fig. 12: Pipe cut and deburred
NOTICE
malfunction that is due to contamination.
▶
If a contaminated operating fluid is used, then install a
filter upstream of the product. The filter mesh-size must be
smaller than 25 µm. The filter ensures problem-free function
-
ing of the product. See chpt. 6.7 Fluid data
.
→
Remove the protective cap that closes the internal-threaded
connection.
→
Observe the installation position that is given on the cali
-
bration plate or in the calibration protocol.
English
Summary of Contents for 8746
Page 59: ......