![Burkert 8746 Operating Instructions Manual Download Page 56](http://html1.mh-extra.com/html/burkert-0/8746/8746_operating-instructions-manual_2832385056.webp)
56
Decommissioning
Type 8746 Profibus, 8746 Analogue
product inter-
nal-threaded
connections in
accordance with
din isO 228/1
pipe
diameter
article number
stainless steel
compression fitting
seal
(1 piece)
G 3/8
1/4''
901555
901580
G 3/8
3/8''
901556
G 1/2
10 mm
901546
901577
G 1/2
12 mm
901548
G 1/2
1/2''
901557
901581
G 1/2
3/4''
901558
G 3/4
12 mm
901549
901578
G 3/4
3/4''
901559
901582
G 1
On request
13.3
Mesh filters
Tab. 32:
Spare parts – Mesh filters
item
article number
MFC: Stainless steel mesh-filter, mesh size 25 µm
676329
13.4
Additional software
Tab. 33: Documentation and software
Product variant Profibus: GSD file
Download from
Bürkert Communicator software
Download from
14
DEcoMMiSSioNiNG
14.1
Safety instructions
DANGER
risk of injury that is due to pressure in the installation or in
the product.
▶
Before working on the installation or product, cut the pres
-
sure. Vent and drain the pipes.
risk of injury from electric shocks.
▶
Before working on the installation or the product, switch off
the power supply. Make sure that nobody can switch the
power supply on.
▶
Observe all applicable accident protection and all applicable
safety regulations for electrical equipment.
WARNING
risk of injury from improper dismantling.
▶
Dismantling must only be performed by trained personnel
using suitable tools.
Risk of injury from dangerous fluids.
▶
Before you disconnect pipes or valves, flush out dangerous
fluids, release pressure in the pipes and drain.
▶
Observe the applicable accident protection and safety regu
-
lations relating to the operating fluid used.
English
Summary of Contents for 8746
Page 59: ......
Page 60: ...www burkert com...