Page 24
DISPENSE VALVE
SERVICE (cont.)
P829
FIG. 14 DISPENSE VALVE
Location:
Dispense valve is located inside the hood directly
above the sprayhead.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the dispense valve and
check the voltage across the white/violet wire and
white/green wire. Connect brewer to the power
source. Place the "ON/OFF" switch in the "ON"
position, press and release the start switch. The
indication must be:
a.) 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
b.) 200 to 240 volts ac for two wire 200, 230 or 240
volt models.
3. Disconnect brewer from the power source.
If voltage is present as described in step 2 proceed to
#4.
If voltage is not present as described, refer to the
wiring diagrams and check the brewer wiring harness.
FIG. 15 DISPENSE VALVE TERMINALS
22978.0000
TL5
TL4
TL3
TL2
TL1
J2
J1
SE
T
LO
CK
LOCK
SET
1
2
3
4
5
6
1 2 3 4 5 6
BUNN
90 psig max operating pressure
Strainer/Flow Control # 22300.033 0
(Repl. Flow Washer #20526.0330)
(Repl. Screen #23721.0000)
.500 gpm FLOW
P2230
WHI/VIO to Timer TL1
WHI/VIO to ON/OFF Switch
WHI/RED to Brew Selector Switch
WHI/GRN to Timer TL4
WHI/GRN to By-Pass Valve
28230 092200
4. Check for continuity across the dispense valve coil
terminals.
If continuity is present as described, reconnect the
wires to the dispense valve and proceed to #5.
If continuity is not present as described, replace the
dispense valve.
5. Check the dispense valve for coil action. Connect
the brewer to power source. Place the "ON/OFF"
switch in the "ON" position, press and release the
start switch. Listen carefully in the vicinity of the
dispense valve for a "clicking" sound as the coil
magnet attracts and repels the plunger.
6. Disconnect the brewer from the power source.
If the sound is heard as described, there may be a
blockage in the dispense valve or the water line to the
sprayhead. Remove the dispense valve and inspect for
wear, and remove waterborne particles.
If the sound is not heard as described, replace the
dispense valve.
Removal and Replacement:
1. Disconnect wires from dispense valve.
2. Drain enough water from the tank so the dispense
valve is above the water level.
3. Remove water lines and hose barb fitting from
dispense valve.
4. Remove dispense valve from the sprayhead panel.
5. Install new dispense valve .
6. Reconnect the water lines, hose barb fitting and
the wires to the dispense valve.
7. Refer to Fig. 15 when reconnecting wires.