Getting Started 2-15
2.3.5 Cooling
Subsystem
Drawer inlets have hot-swappable, 5+1 redundant 120x38 fans for cooling and the AC unit
has non-redundant fans for cooling the AC unit. Fans provide sufficient airflow to cool system
components, CPU, memory and the chipset, even if one of the 6 fans fails. Each fan is
placed around the center of the drawer and memory. HDDs and the DVD are cooled by
suction.
CAUTION:
The server drawer top cover must be installed and closed for proper system cooling.
Cooling fans must be hot-swapped within two minutes. This time period applies only to
the time that the cooling fan is physically removed, not from the time of failure.
2.3.5.1
Cooling Fan LEDs
#
Status of the
cooling fan LED
Description
Green lighted
Cooling fan is working
A
OFF
Cooling fan is OFF
Figure 2-13. NovaScale 3025/3045 Cooling fan LED