Logamatic EMS RC35 user interface - Subject to technical modifications.
31
User menu
5
5.6
Setting the program
The automatic mode ensures automatic switchover between day and night mode at defined times
of day. In the factory setting, 70 °F (21 °C) is set for day mode, and 63 °F (17 °C) for night mode.
Before you select a program (i.e. a heating program), consider the following:
• At what time in the morning should your home be warm? Does this time vary depending on the
day of the week?
• Are there days when you do not need your home to be heated during the day?
• From what time in the evening does your home no longer need to be heated? This too may vary
depending on the day of the week.
1. Open the
User menu
.
2. Select
program
.
3. If your heating system is equipped with more than one heating zone (
Æ
page 26): select the
desired heating zone and confirm. A separate program can be set for each heating zone.
You will then see the following options to choose from:
–
select program
(
Æ
page 32)
–
show current prog.
(
Æ
page 35)
–
change switch point
(
Æ
page 35)
–
enter switch point
(
Æ
page 36)
–
delete switch point
(
Æ
page 37)
–
room temperatures
(
Æ
page 38, not possible for DHW, DHW circulation and solar heating
zones)
4. Recommended: Use the
select program
option to select the program which best corresponds
to your lifestyle.
5. If the standard program needs to be adjusted: change, insert or delete individual switch points.
-or-
6. If you want to create a completely new program:
select program
and set a
new program
.
The
enter switch point
menu item (
Æ
page 36) opens automatically for you to create your
program.
In the factory setting, the program also determines the times for DHW heating and the
operation of the DHW i.e. circulation pump. However, you can also set separate
programs for both functions (
Æ
sections 5.7 and 5.8).