Revision 5
19
th
January 2021
Page | 38
EU DC Fast Charger (50kW & 100kW)
INSTALLATION AND USER’S MANUAL
This document is the
Property of BTCPower
Inc.
and shall not be
copied, reproduced, or used as the basis for sale or manufacture
of apparatus without written permission.
25.
On
Computer Description
, type the charger’s serial number.
26.
Click Change, and then type the charger’s serial number on the
Computer Name
.
27.
Click okay and restart the charger system to reflect changes.
7.
Error Description and Removal
Attention
Attention
Observe all hazard warnings in chapter 1.3
Address
Error
Code
Short description
Description
423
0x0001
Emergency switch ON
After an external emergency factor action, switching to
emergency switch OFF React
0x0002
MC1 contact error or fusion
Abnormality in contact and fusion state of MC1
0x0004
MC2 contact error or fusion
Abnormality in contact and fusion state of MC2
0x0008
MC3 contact error or fusion
Abnormality in contact and fusion state of MC3
0x0010
Relay1 contact error or
fusion
Abnormality in contact and fusion state of Relay1
0x0020
Relay2 contact error or
fusion
Abnormality in contact and fusion state of Relay2
0x0040
Relay3 contact error or
fusion
Abnormality in contact and fusion state of Relay3