Revision 5
19
th
January 2021
Page | 7
EU DC Fast Charger (50kW & 100kW)
INSTALLATION AND USER’S MANUAL
This document is the
Property of BTCPower
Inc.
and shall not be
copied, reproduced, or used as the basis for sale or manufacture
of apparatus without written permission.
50kW / L3S2-50-400-XXX
100kW / L3S2-100-400-XXX
Charging type
DC fast charging and AC type-2 charging
DC fast charging and AC type-2 charging
Outlet options
CCS T2 cable, CHAdeMO cable, AC type-2
socket
CCS T2 cable, CHAdeMO cable, AC type-2
socket
Input AC power
rating
110A, 77kVA @50Hz
190A, 132kVA @50Hz
Input voltage range /-10%(50Hz +/-10%)
/-10%(50Hz +/-10%)
DC output power
rating
50kW
100kW
AC output power
rating
22kW
22kW
DC output voltage
50-1000Vdc
50-1000Vdc
Number of EV
served
2(DC CCS T2 or CHAdeMO, AC type-2)
3(DC CCS T2 and CHAdeMO, AC type-2)
Cable length
4.0m (optional : 6.0m)
4.0m (optional : 6.0m)
CCS cables Max.
current
125A
200A
CHAdeMO cables
Max. current
125A
200A
EMC
Class B(Residential) according to EN
61000-6-1/3
Class A(Commercial) according to EN
61000-6-2/4
Type of
AC-Connection
5-Wire TN-C-S/TN-S/TT system(L1, L2, L3, PE,
N)
5-Wire TN-C-S/TN-S /TT system(L1, L2, L3, PE, N)
Protection
Overcurrent, overvoltage, short-circuit protection, undervoltage, insulation monitoring,
integrated surge protection
Power factor(full
load)
> 0.96
> 0.96
Efficiency
> 94%(peak)
> 94%(peak)
Energy metering
MID metering for AC and DC outlets (Optional : DC metering for DC outlets)
User interface
User interface
15“ LCD touchscreen and physical
buttons
to control display unit
15“ LCD touchscreen and physical buttons to
control display unit
Communication
protocols
OCPP 1.6
OCPP 1.6
RFID Reader
All MIFARE standards an per ISO 14443A/B
All MIFARE standards an per ISO 14443A/B
Emergency button
Yes
Yes
General
characteristics
IP and IK rating
IP-54 and IK-10(housing)
IP-54 and IK-10(housing)
Enclosure type
Steel and Aluminum
Steel and Aluminum
Operational altitude Up to 2000m
Up to 2000m
Operating
temperature range
-30
℃
to +50
℃
-30
℃
to +50
℃
Max. relative
Humidity
<95% non-condensing
<95% non-condensing
Dimensions (H x W x
D)
1884 mm x 738 mm x 809 mm
1884 mm x 738 mm x 809 mm
Mass
365kg
400kg
Certification and
standards
Charging system
IEC 61851-1, IEC 61851-21-2, IEC 61851-23/24, IEC 62196-2/3, IEC/EN 61000
Communication to
the EV
DIN 70121, ISO/IEC 15118-3, CHAdeMO 1.2