Revision 5
19
th
January 2021
Page | 46
EU DC Fast Charger (50kW & 100kW)
INSTALLATION AND USER’S MANUAL
This document is the
Property of BTCPower
Inc.
and shall not be
copied, reproduced, or used as the basis for sale or manufacture
of apparatus without written permission.
9.
Maintenance
All servicing must be performed ONLY by qualified personnel. Do not attempt to
service this Charger yourself.
Make sure to turn off the power to the charger before performing any maintenance
activity.
9.1.1.
Maintenance Precautions
Each of the capacitors in this device have a high voltage for a time after shutting off the input
power supply. Must allow five (5) minutes after powering down before servicing internal
components.
9.1.2.
Maintenance Items Perform periodic checks. Visual Check Items
•
Check for abnormal sound from running fans and power units. If there is abnormal sound,
please contact a BTC Power representative for further assistance.
•
Check for abnormal odor, changes of inner materials, corrosion, anomaly in
appearance, etc., in this device. If there are any anomalies, please contact a BTC
Power representative for further assistance.
•
Check for dust and dirt in this device regularly and, if any is found, clean using
appropriate procedures.
9.1.3.
Replacement of Fixed-Life Components
To prevent the device from failure due to worn out components, it is necessary to replace the
components before they reach the end of their lifespan. Use the following replacement intervals
as a guideline for the estimate of the total running time. Please contact a BTC Power
representative for further assistance when you replace the parts.
•
Power feed cable: Approximately three (3) years.
•
Intake and exhaust filters (as applicable): Approximately three (3) years.
•
Please keep in mind that the replacement interval of each part can vary depending
on, for example, the usage environment of the device.
Attention
Attention
Observe all hazard warnings in chapter 1.3
9.1.4.
Overview of maintenance work
For the safe operation of the charging station, regular maintenance or control
of the safety equipment is required. All the points listed below are considered
mandatory and must be carried out by the operator of the switchgear at the
intervals described.
Table 16 gives an overview of the intended maintenance work. Depending on
the individual conditions of use of the control cabinet, maintenance work may
still be necessary so that the list cannot be considered complete.