7
Electrical connection
54/70
EcoGuide compact web guide control
7.6
Voltage supply
7.6.1 Requirements of the supply grid
The voltage supply of the EcoGuide compact web guide control is
carried out via an external power pack (
Specification see chapter
4.6
).
NOTE
Incorrect voltage supply
can cause damage to the surface of the compact web guide con-
trol.
►
Before connecting the voltage supply, make sure that the pow-
er pack used fulfills the requirements according to chapter 4.6.
7.6.2 Connecting the voltage supply
The voltage supply is connected to the
ekr CON 100
controller in-
tegrated in the
EcoGuide
using a 4-pin micro-style connector M8.
Fig. 30: Contact assignment in the plug connector
Contact
Signal
Wire color Note
1
+24 V
⎓
brown
Power supply
2
reserved
3
GND
blue
Ground
4
reserved
Contact assignment in the plug connector
Connector
Coupling