7
Electrical connection
52/70
EcoGuide compact web guide control
Fig. 28: Flat connector for the equipotential bonding on the controller and bottom frame
Establish the equipotential bonding on the controller
For the connection of a cable ① for the equipotential bonding
(wire cross-section 1.5 – 2.5 mm
2
), please use the push-on con-
nector ② on the flat connector (
) on the back of the controller.
Establish the equipotential bonding on the bottom frame
For the connection of a cable
③
for the equipotential bonding
(wire cross-section 1.5 – 2.5 mm
2
), please use the push-on con-
nector
④
on the flat connector of the bottom frame (see Fig. 28).