Table 4 – Dry Coil Air Delivery* -- Horizontal and Downflow Discharge -- Unit 607C024--060

Unit

Motor

Speed

Wire

Color

 

External Static Pressure (IN. W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

607C024

Low

Blue

CFM

741

638

547

415

---

---

---

---

---

Med-Low

1

Pink

CFM

898

820

738

662

536

---

---

---

---

Medium

Red

CFM

973

887

823

733

665

538

451

---

---

Med-High

Orange

CFM

1140

1064

996

915

840

758

687

564

480

High

Black

CFM

1202

1140

1082

1015

961

881

810

732

631

607C030

Low

Blue

CFM

741

638

547

415

---

---

---

---

---

Med-Low

Pink

CFM

898

820

738

662

536

---

---

---

---

Medium

Red

CFM

973

887

823

733

665

538

451

---

---

Med-High

1

Orange

CFM

1140

1064

996

915

840

758

687

564

480

High

1

Black

CFM

1202

1140

1082

1015

961

881

810

732

631

607C036

Low

Blue

CFM

1295

1234

1182

1126

1075

1016

955

898

857

Med-Low

1

Pink

CFM

1345

1282

1235

1194

1140

1095

1027

974

921

Medium

Red

CFM

1505

1452

1413

1358

1323

1282

1234

1169

1130

Med-High

Orange

CFM

1545

1492

1449

1411

1362

1313

1278

1231

1188

High

Black

CFM

1705

1643

1607

1568

1518

1483

1448

1404

1360

607C042

Low

Blue

CFM

1295

1234

1182

1126

1075

1016

955

898

857

Med-Low

Pink

CFM

1345

1282

1235

1194

1140

1095

1027

974

921

Medium

Red

CFM

1505

1452

1413

1358

1323

1282

1234

1169

1130

Med-High

1

Orange

CFM

1545

1492

1449

1411

1362

1313

1278

1231

1188

High

Black

CFM

1705

1643

1607

1568

1518

1483

1448

1404

1360

607C048

Low

Blue

CFM

1445

1389

1341

1281

1236

1189

1139

1072

1027

Med-Low

1

Pink

CFM

1678

1635

1602

1558

1513

1474

1438

1404

1349

Medium

Red

CFM

1962

1915

1880

1843

1794

1753

1711

1675

1628

Med-High

Orange

CFM

2131

2088

2065

2013

1982

1941

1888

1860

1785

High

Black

CFM

2461

2409

2339

2286

2192

2140

2062

1968

1874

607C060

Low

Blue

CFM

1448

1321

1282

1235

1192

1145

1101

1057

1011

Med-Low

Pink

CFM

1722

1675

1614

1543

1499

1442

1408

1356

1308

Medium

1

Red

CFM

1887

1847

1783

1726

1677

1625

1578

1527

1432

Med-High

Orange

CFM

2055

2008

1958

1927

1900

1768

1685

1581

1458

High

Black

CFM

2292

2238

2158

2049

1935

1840

1732

1635

1513

* Air delivery values are without air filter and are for dry coil (See 607C Wet Coil Pressure Drop Table).

1

Factory---shipped cooling/heat pump heating speed

NOTE

: Deduct field---supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting.

Table 5 – 607C Wet Coil Pressure Drop (in. W.C.)

UNIT SIZE

STANDARD CFM (S.C.F.M)

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

024

0.06

0.07

0.08

0.09

0.1

030

0.12

0.15

0.19

0.23

0.27

036

0.07

0.11

0.18

0.26

0.35

042

0.04

0.07

0.1

0.15

0.21

048

0.11

0.14

0.17

0.22

0.28

060

0.1

0.17

0.23

0.31

0.36

Table 6 – Filter Pressure Drop Table (in. W.C.)

FILTER SIZE

in. (mm)

CFM

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

20X20X1

(508X508X25)

0.05

0.07

0.08

0.1

0.12

0.13

0.14

0.15

20X24X1

(508X610x25)

.09

.10

.11

.13

.14

.15

.16

24X30X1

(610X762x25)

0.04

0.05

0.06

0.07

0.07

0.08

0.09

0.1

24X36X1

(610X914X25)

0.06

0.07

0.07

0.08

0.09

0.09

0.10

0.11

0.12

0.13

0.14

0.14

Table 7 – Electric Heat Pressure Drop Table

Small Cabinet: 024--036 cfm

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

5kw

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.02

0.04

0.06

0.07

7.5 kw

0.00

0.00

0.00

0.00

0.00

0.00

0.02

0.03

0.05

0.07

0.08

0.09

10 kw

0.00

0.00

0.00

0.00

0.00

0.02

0.04

0.06

0.07

0.09

0.10

0.11

15 kw

0.00

0.00

0.00

0.02

0.04

0.06

0.08

0.10

0.12

0.14

0.16

0.18

20 kw

0.00

0.00

0.02

0.04

0.06

0.08

0.09

0.11

0.13

0.15

0.17

0.19

Electric Heat Pressure Drop Table (in. W.C.)

Large Cabinet 042--060 cfm

1100

1200

1300

1400

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

5kw

0.00

0.00

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

7.5 kw

0.00

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

10 kw

0.00

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

15 kw

0.00

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

0.14

0.15

20 kw

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.13

0.14

0.15

0.16

607C

Summary of Contents for 607C024

Page 1: ...Piston 21 Pressure Switches 22 Loss of Charge Switch 22 High Pressure Switch 22 Copeland Scroll compressor Puron Refrigerant 22 C99062 Fig 1 Unit 607C Refrigerant System 22 Refrigerant 22 Compressor...

Page 2: ...The slab should extend approximately 2 in 51 mm beyond the casing on all 4 sides of the unit Do not secure the unit to the slab except when required by local codes Ground Mount The unit may be install...

Page 3: ...he brackets to the unit PROPERTY DAMAGE HAZARD Failure to follow this warning could result in personal injury death or property damage Rigging bracket MUST be under the rain lip to provide adequate li...

Page 4: ...4 A08084 Fig 2 607C024 030 Unit Dimensions 607C...

Page 5: ...5 A08085 Fig 3 607C036 060 Unit Dimensions 607C...

Page 6: ...c heaters require 90 degree elbow in supply duct WARNING When designing and installing ductwork consider the following 1 All units should have field supplied filters or accessory filter rack installed...

Page 7: ...BTyp Supply opening B x C Long Support D 445 16 Return opening B X C Insulated deck pan Short Support CTyp bracket 1126 mm C00076 UNIT SIZE CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM 607C024 030...

Page 8: ...ield supplied 3 4 in PVC or field supplied 3 4 in copper pipe at outlet end of the 2 in 51 mm trap See Fig 11 Do not undersize the tube Pitch the drain trough downward at a slope of at least 1 in 25 m...

Page 9: ...rmostat through the control wiring inlet hole grommet Fig 2 and 3 and into the low voltage splice box Provide a drip loop before running wires through panel Secure and strain relief all wires so that...

Page 10: ...0 11x10 279x254 3 4 1400 11x10 279x254 3 4 1600 11x10 279x254 1 0 1750 11x10 279x254 1 0 HIGH PRESSURE SWITCH psig Cutout Reset Auto 650 15 420 25 LOSS OF CHARGE LOW PRESSURE SWITCH Liquid Line psig C...

Page 11: ...11 Duct Covers C00092 Fig 10 607C with Duct Covers On Shown with optional louvers 1 25 mm MIN 2 51 mm MIN TRAP OUTLET A08001 Fig 11 Condensate Trap 607C...

Page 12: ...12 A08024 Fig 12 Wiring Schematics 208 230 1 60 607C...

Page 13: ...13 A08025 Fig 13 Wiring Schematics 208 230 3 60 607C...

Page 14: ...14 A08026 Fig 14 Wiring Diagram 460 3 60 607C...

Page 15: ...the unit for proper control operation as follows 1 Place room thermostat SYSTEM switch or MODE control in OFF position Observe that blower motor starts when FAN mode is placed in FAN ON position and s...

Page 16: ...efrigerant leak refer to Check for Refrigerant Leaks section Indoor Airflow and Airflow Adjustments All 607C blower motors are factory wired for nominal cooling airflow operation at minimum external s...

Page 17: ...control which includes a field selectable time period DIP switch 1 and 2 on the board between defrost cycles of 30 60 90 or 120 minutes factory set at 60 minutes To initiate a forced defrost two optio...

Page 18: ...eplace the filter with the same dimensional size and type as originally installed See Table 1 for recommended filter sizes Inspect air filter s at least once each month and replace throwaway type or c...

Page 19: ...2292 2238 2158 2049 1935 1840 1732 1635 1513 Air delivery values are without air filter and are for dry coil See 607C Wet Coil Pressure Drop Table 1 Factory shipped cooling heat pump heating speed NOT...

Page 20: ...ith a mild detergent and water solution Rinse coils with clear water using a garden hose Be careful not to splash water on motors insulation wiring or air filter s For best results spray condenser coi...

Page 21: ...ontrols and wiring replace all the panels Start the unit and observe at least one complete cooling cycle to ensure proper operation If discrepancies are observed in operating cycle or if a suspected m...

Page 22: ...amic suction or discharge valves and it is more tolerant of stresses caused by debris liquid slugging and flooded starts The compressor is equipped with an internal pressure relief port The pressure r...

Page 23: ...evice wired into control circuit low voltage It shuts off the compressor if abnormally low pressures are present in the refrigeration circuit NOTE Because these switches are attached to refrigeration...

Page 24: ...driers with rated working pressures less than 600 psig S Do not leave Puron suction line filter driers in line longer than 72 hours S Do not install a suction line filter drier in liquid line S POE o...

Page 25: ...Defective run start capacitor overload or start relay Determine cause and replace Defective thermostat Replace thermostat Faulty condenser fan motor or capacitor Replace Restriction in refrigerant sys...

Page 26: ...OLTAGE __________________________________ COMPRESSOR AMPS_________________________________ INDOOR EVAPORATOR FAN AMPS___________ TEMPERATURES OUTDOOR CONDENSER AIR TEMPERATURE ___________DB RETURN AIR...