Table 1 – Physical Data -- Unit 607C
UNIT SIZE
607C024
607C030
607C036
607C042
607C048
607C060
NOMINAL CAPACITY (ton)
2
2.5
3
3.5
4
5
OPERATING WEIGHT
}
(lb)
(kg)
306
139
316
143
371
168
412
187
432
196
462
210
COMPRESSOR QUANTITY
1
TYPE
SCROLL COMPRESSOR
REFRIGERANT
R---410A
Refrigerant (R---410A) Quantity (lb)
Quantity (kg)
9.5
4.3
10.5
4.8
9.0
4.1
14.0
6.4
17.0
7.7
16.0
7.3
METERING DEVICE ID
TXV
ORIFICE OD (in.)
(mm)
0.032 (2)
.81
0.038 (2)
.97
0.040 (2)
1.02
0.038 (Left OD Coil)
0.040 (Right OD Coil)
.97/102
0.040 (2)
1.02
0.049 (2)
1.24
OUTDOOR COIL
Rows... Fins/in.
face area (sq. ft.)
2...21
13.6
2...21
15.4
2...21
13.6
2...21
19.4
2...21
19.4
2...21
23.3
OUTDOOR FAN
Nominal Airflow (CFM)
Diameter Motor HP (RPM)
2500
22
1/8 (825)
2600
22
1/8 (825)
3000
22
1/4 (1100)
3500
22
1/8 (825)
3500
22
1/4 (1100)
3800
22
1/3 (1100)
INDOOR COIL
Rows... Fins/in.
face area (sq. ft.)
3...17
3.7
3...17
3.7
3...17
4.7
3...17
4.7
3...17
5.7
4...17
5.7
INDOOR BLOWER
Nominal Cooling Airflow (CFM)
Size (in.)
(mm)
Motor (HP)
800
10x10
254x254
1/2
1000
10x10
254x254
1/2
1200
11x10
279x254
3/4
1400
11x10
279x254
3/4
1600
11x10
279x254
1.0
1750
11x10
279x254
1.0
HIGH---PRESSURE SWITCH (psig)
Cutout
Reset (Auto)
650
±
15
420
±
25
LOSS---OF---CHARGE/LOW---PRESSURE
SWITCH
(Liquid Line) (psig)
Cutout
Reset (Auto)
20
±
5
45
±
10
20
±
5
45
±
10
RETURN---AIR FILTERS*
{
throwaway (in.)
(mm)
20x20x1
508x508x25
20x24x1
508x610x25
24x30x1
610x762x25
24x36x1
610x914x25
*Required filter sizes shown are based on the larger of the ARI (Air conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of
300 ft/minute for throwaway type or 450 ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. W.C.
{
If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity.
}
For 460 volt units, add 14 lb (6.4 kg) to the weight.
Table 2 – Minimum Airflow for Reliable Electric Heater Operation (CFM)
SIZE
607C024
607C030
607C036
607C042
607C048
607C060
AIRFLOW (CFM)
800
1025
1250
1400
1710
1800
INDOOR
THERMOSTAT
DISCONNECT
PER NEC*
FROM
POWER
SOURCE
RETURN
AIR
TOP COVER
*NEC
- NATIONAL ELECTRICAL CODE
C00063
Fig. 9 -- Typical Installation (Shown with optional louvers)
607C
Summary of Contents for 607C024
Page 4: ...4 A08084 Fig 2 607C024 030 Unit Dimensions 607C...
Page 5: ...5 A08085 Fig 3 607C036 060 Unit Dimensions 607C...
Page 12: ...12 A08024 Fig 12 Wiring Schematics 208 230 1 60 607C...
Page 13: ...13 A08025 Fig 13 Wiring Schematics 208 230 3 60 607C...
Page 14: ...14 A08026 Fig 14 Wiring Diagram 460 3 60 607C...