Technical data
and start-up
EVB1-350/400-40-HP
90
NAME
CODE (HEX)
DESCRIPTION
START BIT BIT LENGTH TRANSMISSION
MODE
CYCLE TIME
UNIT
BMS_CMD_BALANCING_EN Clearance for balancing
2
1
Cyclic
-
-
BMS_CMD_RESET_AH
Resetting AH meter (BCM_Ah
and BATT_DoD). Precondition:
BMS_State =
BMS_NLG_CHARGER
3
1
Cyclic
-
-
BMS_CMD_FAN
0x0 = Automatic
0x1 = FAN off
0x2 = FAN 10%
0x3 = FAN 20%
0x4 = FAN 30%
0x5 = FAN 40%
0x6 = FAN 50%
0x7 = FAN 60%
0x8 = FAN 70%
0x9 = FAN 80%
0xA = FAN 90%
0xB = FAN 100%
8
4
Cyclic
-
-
BMS_PARAM_RX
0x400
-
-
-
NoMsgSendType
0
-
BMS_PARAM_TX
0x401
-
-
-
NoMsgSendType
0
-
CCU_Cell
0x302
-
-
-
Cyclic
10
-
CCU_Index
Current cell index
0
8
Cyclic
-
-
CCU_Number
Cell block (currently read by cell
index)
8
8
Cyclic
-
-
CCU_V
Voltage of the cell currently
being depicted by the cell index
24
16
Cyclic
-
mV
CCU_T
Temperature of the cell block
currently being depicted by the
CCU_Number
40
16
Cyclic
-
°C
CCU_Max
0x301
-
-
-
Cyclic
10
-
CCU_V_HIGH_PEAK
Highest cell voltage over a
period of 1 ms
8
16
Cyclic
-
mV
CCU_V_LOW_PEAK
Lowest cell voltage over a period
of 1 ms
24
16
Cyclic
-
mV
CCU_T_HIGH
Highest cell block temperature
40
16
Cyclic
-
°C
CCU_T_LOW
Lowest cell block temperature
56
16
Cyclic
-
°C
CCU_V
0x300
-
-
-
Cyclic
10
-
CCU_V_HIGH
Highest cell voltage
8
16
Cyclic
-
mV
CCU_V_HIGH2
Second highest cell voltage
24
16
Cyclic
-
mV
CCU_V_LOW2
Second lowest cell voltage
40
16
Cyclic
-
mV
CCU_V_LOW
Lowest cell voltage
56
16
Cyclic
-
mV